Dometic MCS6 Instrucciones De Montaje página 26

Ocultar thumbs Ver también para MCS6:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 105
Installation
!
WARNING!
 Do not tighten the threaded connections too firmly. Otherwise cracks
may form within hours or days.
 Before you start up the boat, check for any leaks. If you are unsure of
how to proceed, contact a qualified ship's mechanic. Otherwise there
is a danger of the boat sinking. This can result in death or injury to per-
sons.
8.9.2
Duct Kit Installation
I
NOTE
 Unit shown with blower rotated to vertical position.
 Dimensions and part numbers see "Scope of Delivery" on page 11.
Key to fig. 6, page 6
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
26
Description
Ducting
Supply-air grille
Depth behind supply-air grille
Return-air grille
Control panel
Electrical harness
Condensate drain to sump
Hose barb assembly
Seawater outlet
Seawater inlet
Mounting bracket
Air conditioning unit
Electrical box
MCS6, MCS12, MSC16

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Mcs12Mcs16

Tabla de contenido