30" ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
Grounding Instructions (3-Wire
Connections only)
A ground strap is installed on this range which connects
the center terminal of the terminal block (Neutral) to the
range chassis. The ground strap is connected to the range
by the center, lowest screw (See Fig. 13). The ground
strap must not be removed unless National, State or Local
Codes do not permit use of a ground strap.
NOTE: If the ground strap is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.
5C. 3 & 4-WIRE PERMANENT WIRE
CONNECTIONS
3 - Wire Permanent Connection - follow Steps 1,2 & 5
below. 4 - Wire Permanent Connection - follow Steps
1 thru 5 below. Before wiring the range, review the
suggested power source location drawings in Fig. 3. If
connecting to a 4-Wire electrical system (new branch-
circuit or mobile home requires 4-Wire connection):
1. (3 & 4 - Wire Permanent Connections) Follow the
manufacturer's installation instructions supplied with
the strain relief and install.
2. (3 & 4 - Wire Permanent Connections) Strip insulation
away from the ends of the permanent wiring for Line
1, Line 2, Neutral (also strip ground wire on 4-Wire
Connections). Tighten all 3 wire leads to the terminal
block (Follow wire locations shown in Fig. 14).
IMPORTANT NOTE: DO NOT LOOSEN the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss
of electrical connection may occur if these 3 nuts are
loosened or removed. NOTE: For 3-Wire Permanent
Connections skip Steps 3 & 4 and continue with
Step 5.
3. (4-Wire Permanent Connection ONLY) Disconnect
the ground strap. Remove the factory installed ground
screw & plate to release the factory installed copper
ground strap from frame of the appliance. Cut and
discard the copper strap from the terminal block. KEEP
the ground screw, ground plate and go to Step 4.
4. (4-Wire Permanent Connection ONLY) Connect the
ground wire lead (Green) to the frame of the appliance
using the ground screw & plate as shown in Fig. 15.
Be sure to install using the same hole in the frame
where the ground screw was originally installed.
5. (3 & 4 - Wire Permanent Connections) Make sure all
connections are tightened securely and replace the
rear access cover (See Fig. 9).
6. Carefully Slide Range Into
Final Location
Be sure to provide all the adequate clearances and dimensions
shown in Figs. 1, 2 & 3 before moving appliance into final
location.
Carefully slide range into final position while inserting rear
leveling leg into and FULLY ENGAGING THE ANTI-TIP
BRACKET (See Fig. 7). Make sure the power cord folds
into the remaining open floor area behind the range Warmer
or storage drawer. Be sure to check the level of the range.
NOTE: Non-terminated field wire compression
connections must be set at 22 in./lbs. or greater. Always
use 10 gauge wire or larger.
NOTE: Non-terminated field wire compression connections
must be set at approximately 22in./lbs. Always use 10 ga.
wire or larger.