CTH
GB
5.2
Extracting asbestos dust
After the extractor is used to ex-
tract asbestos dust in a sealed-
off area, it can no longer be used
in the white area. Exceptions are
only permitted if the asbestos
dust extractor has been completely decon-
taminated by an approved specialist. This
must be recorded in writing and signed by
the approved specialist.
Fixed filters may only be replaced in suitable
areas (e.g. decontamination stations) by an
approved specialist.
The applicable national regulations (for
example TRGS 519) may contain fur-
ther provisions that regulate or restrict
the application areas of the mobile
dust extractor and which must be ob-
served when extracting dust contain-
ing asbestos particles.
6
Operation
WARNING
Unauthorised voltage or frequency!
Risk of accident
X
The mains voltage and the frequency of
the power source must correspond with
the specifications on the machine's name
plate.
X
In North America, only Festool machines
with the voltage specifications 120 V/60
Hz may be used.
6.1
Initial operation
X
Open the locking clips [2-2] and remove
the top section of the machine[2-1].
X
Remove the accessories from the dust
container [2-3] and the packaging!
X
Affix the accompanying sticker in your na-
tional language over the text field on the
warning sign [1-11].
X
Insert the sealing plug [1-1] on the panel
(see Fig. [1a] ).
X
Place a filter bag or safety filter bag in the
dirt trap in accordance with statutory re-
quirements (see Chapter 7.7, 7.8).
X
Replace the top section [2-1] and close
the locking clips [2-2].
18
X
Attach the cable holder to the rear of the
mobile dust extractor (see Fig. [3]).
X
Connect the suction hose to the machine.
6.2
Switch on/off
X
Insert the plug into an earthed socket.
WARNING
Risk of injury from tools starting up un-
expectedly
X
Before setting the switch to the "AUTO" or
"MAN" position, make sure that the con-
nected tool is switched off.
The switch [1-10] serves as an on/off
switch.
Switch position "0"
Appliance socket [1-4] is disconnected from
the power, mobile dust extractor is switched
off.
"MAN" switch position
Appliance socket [1-4] is connected to the
power, the mobile dust extractor starts.
"Auto" switch position
Appliance socket [1-4] is connected to the
power, the mobile dust extractor starts when
the connected tool is switched on.
7
Settings
7.1
Adjusting the hose diameter
X
Adjust the hose diameter adjuster [1-8]
to match the diameter of the connected
hose.
L The monitoring devices will measure the
air speed in the extractor hose correctly
as a result (see chapter 7.9).
7.2
Connecting electric power tools
WARNING
Risk of injury
X
Observe the maximum connected loads
for the appliance socket (see chapter
"Technical data").
X
Make sure that the power tool is switched
off before connecting or disconnecting.
X
Connect the electric power tool to the ap-
pliance socket [1-4].