15. Troubleshooting
Malfunction
Power indicator (1) stays inactive
VITO makes loud noises at
filtration
Power indicator (1) flashes and/or
acoustic indicator is beeping (VITO
80 beeps additionally)
Power indicator (1) and filtration in-
dicator (2) flashing (VITO 80 beeps
additionally)
VITO cannot be started
Line fuse / Ground fault circuit
interrupter (GFCI) blowout
Low filtration performance
Oil splashes at sides / on top
LEDs flash 10 sec. after plugging in
Should other issues appear, get in contact with the customer support or your local dealer!
Contact details on page 2 chapter Legal information.
Possible cause
•
Power cord (8) not plugged in
•
Power cord (8) / connector is
defective
•
Star handles (5) are too loose
•
Rotor scratches on the fryer
•
Rotor defective
•
overheating protection is
activated
•
VITO is tilted more than 15°
•
Strong vibrations
•
Control unit (6) defective
•
Net protection or other electron-
ic components are blocking
•
Rotor defective
•
Circuit overloaded
•
Particle filter is full
•
Pump pipe is blocked
•
Motor is defective
•
Particle filter blocked
•
Too much space between filter
lid and pump filter unit (9)
•
Filter is inserted incorrectly
•
Push button (3) is defective
•
Control unit (6) wet inside
Remedial action
•
Plug in VITO
•
Please contact service
•
Tighten star handles (5)
•
Alter position of VITO in the
fryer
•
Please contact service
•
let the device cool down
•
Check position of VITO
•
Check position of VITO
•
defective turning part
•
Please contact service
•
Change power outlet, elec.
circuit
•
Please contact service
•
Change power outlet, elec.
circuit
•
Change filter
•
Empty pump-filter unit (9)
•
Deep clean (boil-out)
•
Please contact service
•
Change filter / clean unit
•
Adjust filter sealing sheet
•
Insert filter correctly
•
Please contact service
•
Let it dry