Technical Data; Starting Operation - Bosch AL 1815 CV Manual Original

Ocultar thumbs Ver también para AL 1815 CV:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
8 | English

Technical Data

Battery Charger
Article number
Battery charging voltage (automat-
ic voltage detection)
Charging current
Allowable charging temperature
range
Charging time for battery capacity,
approx.
– 1,5 Ah
– 2,0 Ah
– 2,5 Ah
– 3,0 Ah
– 4,0 Ah
– 6,0 Ah
Number of battery cells
Weight according to EPTA-
Procedure 01:2014
Protection class
*Charge condition of the battery approx. 80%. The battery can be removed for immediate use.
**Charging condition of the battery is 97% – 100%.
Operation

Starting Operation

 Observe the mains voltage! The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the mains plug of
the battery charger is plugged into the socket outlet and the
battery 1 is inserted into the charging compartment 4.
Due to the intelligent charging method, the charging condi-
tion of the battery is automatically detected and the battery is
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Meaning of the Indication Elements (AL 1815 CV)
Flashing Battery Charge Indicator 3
The charging procedure is signalled by a
flashing battery charge indicator 3.
Continuous Lighting of the Battery Charge Indicator 3
Continuous lighting of the battery charge indi-
Full
cator 3 indicates that the battery is fully
charged or that the temperature of the battery
is not within the allowable charging temperature range, and
cannot be charged for this reason. The battery is charged as
soon as the allowable charging temperature range is reached.
1 609 92A 4GM | (23.4.18)
AL 1815 CV
2 607 226 0..
2 607 225 9..
V
14,4 – 18
A
1,5
°C
0 – 45
Battery
approx.
Charged**
80%*
min
63
24
min
84
32
min
105
40
min
130
48
min
168
64
min
260
96
4–10
kg
0,38
/ II
When the battery is not inserted, continuous lighting of the
battery charge indicator 3 indicates that the mains plug is in-
serted in the socket and that the battery charger is ready for
operation.
Meaning of the Indication Elements
(AL 1830 CV/AL 1880 CV)
(Fast) Flashing of the Green Battery Charge Indicator 3
The rapid-charging procedure is indicated by
fast flashing of the green battery charge indi-
cator 3.
Note: The rapid-charging procedure is only possible when the
battery temperature is within the allowable charging temper-
ature range, see section "Technical Data".
(Slow) Flashing of the Green Battery Charge Indicator 3
When the charging condition of the battery is
approx. 80 %, the green battery charge indi-
cator 3flashes slowly.
The battery can be removed for immediate use.
Continuous Lighting of the Green Battery Charge Indica-
tor 3
Continuous lighting of the green battery
Full
charge indicator 3 indicates that the battery is
fully charged.
When the battery is not inserted, continuous lighting of the
battery charge indicator 3 indicates that the mains plug is in-
serted in the socket and that the battery charger is ready for
operation.
AL 1830 CV
AL 1880 CV
2 607 226 1..
14,4 – 18
14,4 – 18
3,0
0 – 45
0 – 45
Battery
approx.
Battery
Charged**
80%*
Charged**
33
12
45
22
60
25
72
30
95
27
130
45
4–10
4–10
0,40
/ II
Bosch Power Tools
8,0
27
30
36
46
35
62
0,60
/ II

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Al 1830 cvAl 1880 cv

Tabla de contenido