I GB
SAFETY DEVICE DISABLING DIP-SWITCHES
Use these dip-switches (detail 7 of fig. L) to cut out the unconnected safety inputs.
When the dip-switch is ON (Cut-out) it acts as a jumper between the Common (term. 6) and one of these 5 inputs.
Function
n.
off on
BSC
1
BSA
2
FT1
3
FT2
4
STP
5
CONFIGURATION DIP-SWITCHES
Select the options required and perform a reset (part. 10, fig. L) to render the changes operational.
Function
n.
off on
Step-by-step
input
1
and
2
radio channel
mode (CH1)
3
N. C.
4
5
Preflash
Re-closure
6
Timer
Output US1.
7
Clean
contact
Release
8
thrust
9
Slowdown
Closing
10
thrust
11
1 - 2 motors
Reclosing after
12
the photoelectric
cells
45
Modo
Description
With closing sensitive edge installed
Cut-out
Closing sensitive edge input disabled. Warning! Terminal no. 7 must not be connected.
With closing sensitive edge installed
Cut-out
Opening sensitive edge input disabled. Warning! Terminal no. 8 must not be connected.
With photocell installed
Cut-out
Photocell input disabled. Equivalent to connecting terminal no. 9 to the common
With photocell installed
Cut-out
Photocell input disabled. Equivalent to connecting terminal no. 10 to the common
With STOP button installed
Cut-out
STOP input disabled. Equivalent to connecting terminal no. 11 to the common
Modo
Description
Open - Stop -
During opening, upon pressing the P/P button the gate stops, pressing it again the gate closes.
Close
During closing, upon pressing the P/P button the gate stops, pressing it again the gate opens.
During opening, upon pressing the P/P button the gate stops for a few seconds and then closes.
Open - Close
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
During opening, pressing the P/Pbutton has no effect. During the pause, pressing the P/Pbutton has no
Always opens
effect.
"Condominium"
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
Opens-Closes
During opening, pressing the P/Pbutton has no effect. During the pause, upon pressing the P/Pbutton the
with no reversal
gate closes.
during opening
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
OFF
The flashing light operates together with the motor.
ON
The flashing light operates 5 seconds before any operation.
After one complete opening, the control unit only closes again with a manual control.
OFF
ON
After one complete opening, the control unit closes automatically after the programmed pause time.
This contact indicates the gate status. The relay is activated at the start of opening and turns off only
Dray contact
when closing is complete.
II° Receiver
Only available if a two-channel radiocard is inserted in the pre-installed connector (det. 21 of fig. L).
channel (OC2)
Function cut out.
OFF
The release thrust releases the electric lock.
ON
The gate leaf with M1 carries out a short closing pulse before opening.
OFF
There is no slowdown in the last part of travel.
ON
With the slowdown function connected, the motor halves its speedtowards
The closing thrust is not carried out.
OFF
ON
The control unit ends the closing manoeuvre with a short spurt with motor M1 at full power.
1 Motor
Only motor output M1 is enabled. The pedestrian control partly opens and closes the gate leaf with motor M1
Both motor outputs (M1 and M2) are enabled. The pedestrian control fully opens and closes the gate
2 Motors
leaf with motor M1.
OFF
Function bypassed
The activation of photoelectric cell reduces the pause time for whatever is value previously was to 2
ON
seconds.