were set when the system was shipped out.
Furthermore, this command will delete all logs in the intended
chassis XSCF.
Check the man page of this command before you run it.
Continue?[yes/no](default no): yes
You must check the following points.
1. Have the ability to power cycle the system.
2. Have access to the serial console and hold the serial
console of the
XSCF to confirm the completion of the command.
If you answer "yes" this command will HALT the XSCF when it
completes.
You will need to power cycle the system after the XSCF BOOT
STOP.
Do you really want to continue?
Continue?[yes/no](default no):yes
The initialization of XSCF will be started.
XSCF
: all data clear (exclude SYSTEM ID data)
BACK UP : all data clear (exclude SYSTEM ID data)
XSCF will be automatically rebooted. Afterwards, XSCF will be
initialized.
Continue?[yes/no](default no):yes
Disabling IDIAG prompt complete
Setting FRUID-ROM to writable complete
Clear BB-ID complete
Backup common DB complete
Syncing file systems...
XSCF shutdown request was completed.
6.
Confirme que todos los LED del panel de operación estén apagados.
7.
Retire los cables de alimentación de las unidades de fuente de alimentación.
8.
Cambie los BB-ID a la configuración correcta.
Para obtener más información, consulte
identificar SPARC
9.
Realice los pasos 3 a 8 para BB#01.
10. Conecte el cable de control BB XSCF y el cable de control DUAL XSCF de
BB#00 y BB#01.
11. Conecte los cables de alimentación de cada SPARC M12-2S a las unidades de
fuente de alimentación.
12. Conecte el terminal de gestión del sistema al puerto serie del XSCF maestro.
13. Continúe con el trabajo según
complete
"4.1 Configuración del ID (BB-ID) para
M12-2S".
"6.3 Inicio de sesión en el
XSCF".
Apéndice A Solución de problemas