Whirlpool LWFR3100 Instructivo De Instalación, Uso Y Manejo página 31

Estufas a gas 30
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LOCATION REQUIREMENTS
Minimum spaces for installation (these spaces should be followed)
61
GAS SUPPLY REQUIREMENTS
This stove is prepared to work with a moving LP gas tank or a fixed LP gas tank.
To use your stove with natural gas you should contact Whirlpool Service to change the nozzle
and make the necessary adjustments.
The qualified technician should make the conversion on the nozzles of each cooktop burner; the
technician must test the connection and the gas pressure in the oven, the values should be like the
following:
OPERATING LP GAS PRESSURE
2,75 kPa; 2750 Pa; 27,5 mbar;
28cm WATER COLUMN
NOTE: The gas type used for this range is LP. If you wish to use Natural gas with this range you
will need a conversion kit according to the following table. This kit can be ordered from the
Authorized Whirlpool Solution Center. If you don't follow theses indications your stove will generate
soot and will require cleaning service which is not covered by the warranty of this product.
76.2
76.55
MODEL
LWFR3000B LWFR3100B
LWFR3200D LWFR3400D
LWFR3400S LWFR3300D
LWFR5000D LWFR5100S
LWFR7000S
LWFR7100S
LWFR7200S
46
90
OPERATING NATURAL GAS PRESSURE
1,76 kPa; 1760Pa; 17,6 mbar;
18cm WATER COLUMN
Conversion Kit to Natural Gas
W10513462
W10132112
W11209937
W11209938
W11209939
33
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lwfr3200Lwfr3400Lwfr3300Lwfr5000Lwfr7000Lwfr7200

Tabla de contenido