Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
English
Patch panel of the elmeg ICT88 / 880

PABX modules

Various modules can be used for the PABX system The firmware must be loaded prior to installation of the modules. All of the configurati-
on data will then be deleted. You should first make a backup copy of all PABX data and then reset the system to the default state (code "999").
Switch the system off, then mount the modules. Restart the system.
There are three fitting variants possible for the terminating resistors of S0 modules, with terminating resistors soldered in, without termi-
nating resistors and with switchable terminating resistors. Check your module before assembly and install it as appropriate.
Please note that only one module can be inserted into each available PABX slot.
6
1 - USB port
2 - RS232 connection
3 - Jack for the external ISDN port S04: EXT
4 - Jack for the overload protection module S04
5 - Internal / external ISDN port S04: INT/EXT
6 - Switch for the terminating resistors S04
7 - Jack for the external ISDN port S03: EXT
8 - Jack for the overload protection module S03
9 - Internal / external ISDN port S03: INT/EXT
10 - Switch for the terminating resistors S03
11 - Jack for the external ISDN port S02: EXT
12 - Jack for the overload protection module S02
13 - Internal / external ISDN port S02: INT/EXT
14 - Switch for the terminating resistors S02
15 - Internal / external ISDN port S01: INT/EXT
16 - Switch for the terminating resistors S01
17 - Jack for the internal ISDN port S01: INT
18 - Jack for the overload protection module S0119
19 - Input for external music on hold with volume control
20 (volume)
21 - Functional ground
22 - Connection for analog terminal devices 7 and 8 (a/b7
a/b8)
23 - Jack for the overload protection module
24 - Connection for analog terminal devices 5 and 6 (a/b5
a/b6)
25 - Jack for the overload protection module
26 - Connection for analog terminal devices 3 and 4 (a/b3
a/b4)
27 - Jack for the overload protection module
28 - Connection for analog terminal devices 1 and 2 (a/b1
a/b2)
29 - Jack for the overload protection module
30 - 12V output = max. 25 mA

Publicidad

Tabla de contenido
loading

Tabla de contenido