To use the branch connectors, proceed as follows:
➤
Insert the cable to be tapped in the front groove of the cable connector
(i A, page 10).
➤
Insert the end of the new cable up to approx. 3/4 of the way into the rear groove
(i B, page 10).
➤
Use a pair of combination pliers to close the connector by pressing the metal pin in.
This creates an electrical connection (i C, page 10).
➤
Press down the safety cap until it snaps into place.
➤
Check that the connection is secure by lightly tugging the cable (i D, page 10).
6.3
Creating clean soldering joints
Proceed as follows to solder a cable to the original cables:
➤
Strip approx. 10 mm of insulation from the end of the original cable (j A, page 10).
➤
Strip approx. 15 mm of insulation from the end of the cable to be connected (j B,
page 10).
➤
Wind the cable to be connected around the original cable and solder the two cables
together (j C, page 10).
➤
Insulate the two cables with insulating tape (j D, page 10).
Proceed as follows to solder two cables together:
➤
Strip the two cables (k A, page 10).
➤
Place a shrink sleeve with a length of approx. 20 mm over the cable (k B, page 10).
➤
Twist the cables together and solder them (k C, page 10).
➤
Place a shrink sleeve over the soldered point and heat it briefly (k D, page 10).
General information on the electrical connections