8.1 Oil change.
Keep the engine running during 5 or 10 minutes, so that the oil can reach some
temperature and decrease its viscosity (more liquid). In this way, it will be easier to
extract it completely.
1. Remove the oil refill cap (A) turning counterclockwise. Keep the cap in a
visible place.
2. Place a suitable container to collect the used oil, near of the generator.
3. Tilting the generator (B), let all oil pours into the container. Keep the
generator tilted during several minutes to ensure that the most part of the oil
was expelled.
4. Once all engine oil has been extracted, clean up any spillages.
5. Refill with oil, according to the recommendations of chapter: 4.2 Oil filling
and checking.
IMPORTANT: To safeguard the environmental regulations, the used oil must be
placed in a sealed container and delivered to a service station for recycling. Do not
put it in the trash or spill it on the ground.
58