Enter Firing Curve / Program
The micro-processor control unit TC 304 allows you to achieve high-precission control
and reproducible results with your kiln . The firing curve of the TC 304 is displayed in
the following diagram . It consists of a number of segments:
Delay time / Delay of Program Start:
The controller waits for the preset period of time until it starts the actual firing process .
With this function the firing process can be started automatically, e .g . at night .
Press the key , in order to reach the input field „t0" (delay time).
Enter a value between 0.00 (no delay time) and 9.59 (hours.minutes) by using
the
or
keys.
Heating up to 1. dwell temperature:
The kiln is heated up in the preset speed; input in degree Celsius per hour .
Press the key , to reach the input field „rmp1" (1 heating ramp). Enter a
value between 1 and 999°C / h, or select SKIP (full load heating) by using the
or
keys.
Temperature for 1. dwell time:
The kiln is heated at the speed set above until it reaches the 1 . dwell temperature,
input in degree Celsius .
Press the key , to reach the input field „tmp1" (1 dwell temperature).
Enter a value between 20 and 1320°C by using the
First, choose the program slot on
which you wish to store the new pro-
gram . Press the prog key until the
desired program slot (1 to 5) appears .
T0
RMP1
TMP1
or
keys.
17