20. Loading the refrigerant pag.6-7-8

DANGER! Refrigerant Gas. Explosion. Asphyxiation, alteration of heart pace, burns
from frost, anaesthetic effects.
Only specifically trained technicians can charge the refrigerant according to European
Regulation 842/2006
Cabinets with
remote unit
Cabinets with
built-in unit
Refrigerant
This cabinet contains HFC refrigerant with high global warming effect (GWP
gases used
Type of gas
R 410A; GWP
R 404A; GWP
Procedure
Step
1
2
3
4
5
6
Cabinets with built-in unit are hermetically sealed and the refrigerant charge is less than 3 kg.
It is therefore not subject to the obligation of a plant booklet or periodic checks of the loss of
refrigerant (Presidential Decree n.147 of 15 February 2006 Article 3 and 4)

21. Dismantle the cabinet

i
This product is made up by 75% of recyclable materials.
Preparazione
Obligations
hand over the components of the cooling circuit intact to specialist centers
i
05060144 01 22/08/2014
for the type and weight of refrigerant please consult the serial plate (cap.9.)
for refrigerant load please refer to diagram pag.6-7
= 2088
(100)
= 3750
(100)
check refrigernat leaks using a specific leak detector
empty the entire system and recover the gas with a suitable pump
remove the cause of the leak
apply vacuum to the entire system
load the system with the same type and quantity of gas, refer to the
serial plate (cap.9.)
load through the special valve provided next to the compressor
recover the coolant
remove the lubricating oil.
dismantle the cabinet in accordance with the local laws on waste disposal
and in respect of the environment in which we live
this product is considered by the Legislature in force to be a dangerous
waste and therefore its separate waste collection is obligatory and it
cannot be treated as domestic waste nor assigned to a waste dump.
for refrigerant recovery
All these operations as also transport and waste treatment must be
exclusively performed by specialized and authorized personnel.
refer to system's user guide
General
these types of gases used in built-in unit models
OSCARTIELLE S.p.A. belong to:
- HFC family, e.g. fluoride gas with high green-
house effect (GWP) regulated by the Kyoto
protocol.
i
Check the rating plate or the adhesive
label on the compressor for which of these
two gases circulates in the equipment)
therefore:
Action
Polaris D - Mini Polaris D
English
63