Descargar Imprimir esta página

Equipment; Fittings Technical Data; Steam Generator Technical Data - HOESCH SenseSation Serie Instrucciones De Montaje

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
For the safety reasons this device should not be used by physically and mentally disabled people (and children) or by
people without relevant experience or knowledge, unless they use it, under supervision of relevant persons or get the
instruction how to use it.
Children should use this product only under adult's supervision.
Attention: due to high temperature within the working area of steam jet and at steam outlet, direct skin contact
should be avoided.
- warning! Hot surface!
Silicone must be provided by the customer. Please note that maintenance joints must be cleaned.
02

Equipment

Back walls made of toughened safety glass with EverClean coating.
Frameless glazing made of toughened safety glass with EverClean coating.
Roof, made of sanitary-grade acrylic (PMMA) and glass.
Shover tray (optionally) made of sanitary-grade acrylic (PMMA)
Capacitive integrated control panel.
Steam generator with automatic cleaning and descaling Nominal voltage 230 V, 50/60 Hz.
Steam jet with blower.
Aroma package, inclusive dispenser.
Fittings (chrome-plated) consisting of:
hand shower, rain shower, kneipp hose, 8 adjustable back jets, thermostat 1/2˝, 1 closing valve.
Rain shower and back jets electronically operated.
Sound-module consists of MP3-Player (USB-interface),
radio, 2 tweeter speakers and 1 bass speaker.
USB stick with 10 hours of music.
Heating element with a six-step control inclusive temperature controller,
Rated consumption: 1800 watt, nominal voltage 230 V, 50/60 Hz.
LED-stripe with colour changer in the roof frame.
One stool made of stainless steel and PU seat.

02.01 Fittings technical data

Minimum fl ow pressure:
Recommended fl ow pressure:
Hot water temperature:
Recommended hot water temperature: 60-70°C
Temperature range:
Safety cut-off:

02.02 Steam generator technical data

art.-no.
Steam generator
Voltage
Fuse protection
Line cross section
Water connection (Cold Water + Hot Water)
Steam output
100 kPa
200-500 kPa
max. 90°C
20-60°C
38°C
1L, XL, 1R, XR, 2L, YL, 2R, YR
4,2 kW
1N~230 V, 50/60 Hz
1 x 20 A
3 x 2,5 mm
2
R½"
8 kg/h
1V, XV, 2V, YV, 1F, XF
6,3 kW
3N~400 V, 50/60 Hz
3 x 10A
5 x 2,5 mm
2
R½"
10 kg/h
13
GB

Publicidad

loading