Maintenance and cleaning
Replacing the UVC lamp
Replace the UVC lamp after max. 8,000 operating hours (this corresponds to approx. one pond season with continuous
operation). This ensures optimum filtering performance.
● Only use UVC lamps whose identification and capacity data correspond to the information on the type plate.
(See Technical Data)
Prerequisite: The device head is removed. (See Removing the unit head)
1. Remove the cleaning rotor.
2. Unscrew the clamping screw counter-clockwise
3. Remove the quartz glass including the O ring towards
the front with a slight turning movement.
4. Pull out the UVC lamp and replace.
5. Carefully push the quartz glass including the O ring
into the unit head up to the stop, fit the clamping screw
and tighten up to the stop by turning clockwise.
○ Clean the O ring, replace if damaged.
○ Ensure that the O ring is located in the gap between
the unit head and the quartz glass.
6. Push the cleaning rotor onto the quartz glass.
○ Ensure that it is correctly positioned.
7. Fit the unit head. (See Fitting the unit head)