Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Prior to reaching into the water, switch off the mains voltage to all units used in the water.
• Switch off the mains voltage prior to carrying out work on the unit.
Note! If the water flow is suddenly interrupted downstream of the outlet (e.g. with a slide valve), this can lead to a
brief increase of pressure of more than 1 bar (water hammer).
Possible consequences: The unit may be damaged.
Protective measures:
• Switching off: First switch off the pump, then close the slide valve. If the unit is operated in a filter system, first take
the filter system out of operation.
• Switching on: First open the slide valve, then switch on the pump. If the unit is operated in a filter system, start up
the filter system last.
• Install the slide valve upstream of the inlet.
When using filter starter, medicines or pond water treatments, leave the UVC clarifying unit switched off for at
least 36 hours so as not to impair their efficacy.
Prerequisite
● Switch the pump on first, then switch on the UVC clarifying unit.
● Check all connections for leaks.
Switching ON/switching OFF
1. Switching on: Insert the power plug into the socket. The unit switches on immediately
2. Switching off: Disconnect the power plug.
Check the function
● The function display is lit when the UVC lamp is switched on.
● An alternating light/dark blue glow in the inspection window
indicates that the cleaning rotor is rotating.
Setting the bypass
The flow rate is controlled by the bypass. Depending on the setting, part of the water flows from the inlet directly out via the
opposite outlet. The remaining part of the water is irradiated by the UVC light and flows out via the second outlet. Maximum
cleaning capacity is only achieved with an optimum setting.
● Set both rotary handles
to the delivery rate of the
filter pump.