Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
Information on maintenance and care
Clean all components with a damp cloth and do not use
cleaning agents, scouring agents and solvents. Remove
the battery(ies) before storing for longer periods. Store the
device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular
basis to ensure it produces accurate measurement results.
We recommend carrying out calibration once a year.

Technical data

Measurement range
D:S ratio
Infrared accuracy
(ambient temperature
= 25°C)
Probe accuracy
(ambient temperature
= 25°C)
Emission coefficient
Display
Laser
Laser wavelength
Laser class
Power supply
Degree of protection
Operating conditions
Storage conditions
Dimensions (W x H x D)
Probe sensor
Weight (incl. batteries)
Technical revisions reserved. 07.17
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=thein
ThermoInspector
-60°C ... 350°C
8:1
± 1,0°C + 0,1°C/degree (< 0°C)
± 1,0°C (0°C ... 15°C)
± 0,6°C (15°C ... 35°C)
± 1,0°C (35°C ... 65°C)
± 1,5% (> 65°C)
± 1,0°C (< -5°C)
± 0,5°C (-5°C ... 65°C)
± 1,0% (> 65°C)
0.1 ... 1.0 adjustable
LCD with multicolour
backlighting
2-point target laser
650 nm
2 / < 1 mW
Batteries, 2 x 1.5 V, type AAA
IP 54
-20°C ... 70°C, 80% rH,
no condensation,
max. altitude 2000 m
-20°C ... 70°C, 80% rH,
no condensation
40 x 158 x 53 mm
L 95 mm / ø 3,3 mm
146 g
17
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido