LaserLiner EasyCross-Laser Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Checking the vertical line
Position the device about 5 m from a wall. Fix a plumb bob with
a line of 2.5 m length on the wall, making sure that the bob can
swing freely. Switch on the device and align the vertical laser to
the plumb line. The precision is within the specified tolerance if the
deviation between the laser line and the plumb line is not greater
than ± 2.5 mm.
Checking the horizontal line
Position the device about 5 m from a wall
and switch on the cross laser. Mark point B
on the wall. Turn the laser cross approx. 2.5 m
to the right and mark point C. Check whether
the horizontal line from point C is level with point B to within ± 2.5 mm.
Repeat the process by turning the laser to the left.
!
Regularly check the calibration before use, after transport
and after extended periods of storage.
Technical data
Self-levelling range
Accuracy
Operating range (depending
on room illumination)
Laser wavelength
Laser class
Power supply
Operating time
Operating conditions
Storage conditions
Dimensions (W x H x D)
Weight (incl. batteries)
Subject to technical alterations. 18W05
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=eascrolas
EasyCross-Laser
± 3°
± 0.5 mm / m
10 m
635 nm
2 / < 1 mW
3 x 1.5 V alkaline batteries
(typ AAA, LR6)
55 hours (alkaline batteries)
0 ... 50°C, max. humidity 80% rH,
no condensation, max. working
altitude 4000 m above sea level
-10°C ... 70°C,
max. humidity 80% rH
61 x 72 x 62 mm
202 g
2,5 m
B
C
09