VDS-BUS2 Programming
VDS-BUS2 Programming
To programme the lock-release time from the exit button, while in time
programming mode, (having finished programming the lock-release time
from the residence or following the indicator tones), wait 5 seconds before
taking any other action.
5.- At this time a new confirmation tone will sound indicating the change to
entrance hall lock-release programming mode, then subsequently emitting
the aforementioned beeps detailing the time programmed.
6.- Once the current time indicator tones have concluded, or before they
conclude, press any button on the panel, with one press for each second to
be programmed (from 1 to 99 seconds).
To exit programming mode, wait 5 seconds without pressing any key. A "MUOK"
sound will be emitted indicating that you have exited time programming mode.
If you enter time programming mode and do not press any key, this mode will
automatically be exited after 30 seconds.
KEYPAD Programming
You can also programme lock-release times using a BUS2 Direct auxiliary
keypad.
For more information refer to the "BUS2 Direct Panels - Lock-Release
Programming" section of the BUS2 technical manual; code 97462 available
at www.fermax.com.
The connection for the BUS 2 Direct keypad and the BUS2 amplifier is detailed
under Section II of the BUS2 Technical Manual under "Bus2 Direct Panel
Prewiring".
Pag 14
VDS-BUS2 Programming
VDS-BUS2 Programming
To programme the lock-release time from the exit button, while in time
programming mode, (having finished programming the lock-release time
from the residence or following the indicator tones), wait 5 seconds before
taking any other action.
5.- At this time a new confirmation tone will sound indicating the change to
entrance hall lock-release programming mode, then subsequently emitting
the aforementioned beeps detailing the time programmed.
6.- Once the current time indicator tones have concluded, or before they
conclude, press any button on the panel, with one press for each second to
be programmed (from 1 to 99 seconds).
To exit programming mode, wait 5 seconds without pressing any key. A "MUOK"
sound will be emitted indicating that you have exited time programming mode.
If you enter time programming mode and do not press any key, this mode will
automatically be exited after 30 seconds.
KEYPAD Programming
You can also programme lock-release times using a BUS2 Direct auxiliary
keypad.
For more information refer to the "BUS2 Direct Panels - Lock-Release
Programming" section of the BUS2 technical manual; code 97462 available
at www.fermax.com.
The connection for the BUS 2 Direct keypad and the BUS2 amplifier is detailed
under Section II of the BUS2 Technical Manual under "Bus2 Direct Panel
Prewiring".
Pag 14