3 Motor drive adjustment
Commands
1. Press SEL repeatedly until the "FORZA" LED turns on.
Press SET and immediately release: the currently set drive value is displayed (8 levels availa-
2.
ble as per the table).
3. Press SEL until the LED configuration matches the required drive value.
4. Press SET and immediately release it: the "FORZA" LED turns back on (new drive value saved).
At this point, press SEL to select any other programming function or exit programming (all LED
5.
off).
4 Learning work times with 1-motor operations
Commands
Run the gear motor release operation, manually move the door to the fully closed position and
1.
lock the gear motor again.
If electromechanical limit switches are installed, adjust the relevant cam so that the closing
2.
limit switch, in this position, is triggered.
3. Press SEL repeatedly until the "PROG" LED turns on.
Press and hold down the SET key until the "PROG" LED starts to quickly flash indicating that
4.
work time learning has started.
5. Release the SET key.
6. Press START: motor 1 starts opening.
When motor 1 reaches limit stop, press START: motor 1 stops.
WARNING: Even if installed, the opening limit switch is not read in this phase. The
7.
door MUST be stopped in any case by pressing START at the required point. Adjust
the relevant cam so that the opening limit switch is triggered in this position.
Press START: automatic closing time countdown starts.
8.
WARNING: To disable automatic closing, hold down until motor 1 closing starts and skip di-
rectly to point 11.
9. Wait for the required automatic closing time.
10. Press START: motor 1 starts closing.
After several sec. from reaching limit stop (or when reaching any closing limit
11.
switch) the motor automatically stops. The "PROG" LED turns back on, work time
learning has completed.
At this point, press SEL to select any other programming function or exit programming (all LED
12.
off).
10
Function
Drive level
Function
LED status
LED status