Hotpoint Ariston HDAI 9 IX/HA Instrucciones De Uso página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
MAINTENANCE
ATTENTION! Before performing any maintenance operation, isolate the hood
from the electrical supply by switching off at the connector and removing the
connector fuse.
Or if the appliance has been connected through a plug and socket, then the plug
must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the same frequency
with which you carry out maintenance of the fat filters) internally and externally.
Clean using the cloth dampened with neutral liquid detergent. Do not use
abrasive products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to the motor or any
fire damage linked to inappropriate maintenance or failure to observe the above
safety recommendations.
Maintenance of the anti-grease filters
Traps cooking grease particles.
This must be cleaned once a month using non aggressive detergents, either by
hand or in the dishwasher, which must be set to a low temperature and a short
cycle. When washed in a dishwasher, the grease filter may discolour slightly, but
this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Maintenance of the charcoal filter
It absorbs unpleasant odours caused by cooking.
The saturation of the activated charcoal occurs after more or less prolonged use,
depending on the type of cooking and the regularity of cleaning of the grease
filter.
In any case it is necessary to replace the cartridge at least every four mounths.
The carbon filter may NOT be washed or regenerated.
Assembly
Hook the charcoal filter at the back on the metal tongue of the hood first, then on
the front with the two knobs.
Disassembly
Remove the charcoal filter by turning the knobs fixing it to the hood by 90°.
Replacing lamps
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are cooled down.
1.
Using a flat head screwdriver or equivalent tool, carefully pry loose the light
cover.
2.
Remove the damaged light and replace with a new 12 Volt, 20 Watt
(Maximum) halogen light made for a G-4 base SUITABLE FOR USE IN
OPEN LUMINAIRES. Follow package directions and do not touch new light
with bare hands.
3.
Reinstall the light cover. (it will snap shut).
EN
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hdsi 9 ix/haHfi 9 f ix/ha

Tabla de contenido