Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
1. DESCRIPTION
The low-temperature version of the TORTUGA showcase is meant for the preservation of ice-creams
and frozen food (class L), whereas its positive-temperature version is for the preservation of fresh
pre-packed food (class M). TORTUGA display cases are available in two different and lengths, in
various aesthetic styles and with different possibilities, as set forth in the main features section,
which clearly illustrates dimensions too in drawings 1, 2 , 3, 4, 5 on pages 14 and 15.
As for weights, packing included and excluded and packing sizes, see table I on page 16.
A wide variety of optional accessories is also available for enhanced functions. To this respect, con-
tact the authorisedafter-sales service only.
2. TRANSPORTATION
The cabinet is contained in a specially crated package that enables transportation by the use of
fork-lift trucks. Handle the machine on its own pallet or on a similar platform; use a fork lift truck,
either manual or electric, provided that it is adequate for handling such appliances and it has the
requisite lifting capacity (see page 16 - figs. 6 and 7 and table I). Handling is reserved for the au-
thorised after-sales service.
3. DELIVERY AND STORAGE
Prior to accepting the case from the carrier, check the conditions of the package. If it is showing
visible damage, the machine too may have suffered some consequences. If so, unpack the ma-
chine in the presence of the carrier and sign, with reservation, the delivery bill. The manufacturer
disclaims all liability for damage caused by transportation or incorrect handling during storage.
Unpacking is reserved for the authorised after-sales service. Storing temperature must be between
-25°C and +55°C, air humidity between 30% and 95%. Keep the case away from direct sunlight
and from the elements.
4. INSTALLATION AND AMBIENT CONDITIONS
The cabinet must not be installed in premises containing explosive gas substances. It
can neither be used in the open nor exposed to the rain.
Prior to connecting the cabinet, make sure that the rating plate data correspond to the characteri-
stics of the existing electrical system (see page 18 - fig. 11 tab. II). For correct operation, the ma-
chine must be placed on a level floor (see page 17 - fig. 8), far from sources of heat and/or direct
sunlight, doors, windows, fans or ventilation outlets (see page 17 - fig. 9). It must be granted a
reasonable free front area for customer service.
The room where the appliance is installed must comply with the requirements set forth
on page 17, fig. 10 and tab. II.
The installation of the display case is restricted to COSTAN technical after-sales service, who are in
possess of the relevant installation manuals.
5. ELECTRICAL CONNECTION
IMPORTANT: AHEAD OF THE CABINET (excluding the master/slave versions, which are already
equipped with it) THERE MUST BE A MULTIPOLAR CUTOFF SWITCH WITH CONTACTS SPACING AT
LEAST 3 mm AND WITH THE ADEQUATE CIRCUIT-BREAKING POWER (see fig. 18). The position of
TORL-xx
TORTUGA DUAL
Epta Spa - Unità locale: Via degli Alpini 14 - 32020 Limana
(BL) ITALIA Tel. 0437/9681 Telefax 0437/967434
ENGLISH
STATE REVISION
-
ORD.
DATE
27.01.2020
PAGE:
N° DOC.
35/55
UM000396