1. DESCRIPTION
The IMPALA display cabinet is available in two different lenghts (1250-3750 mm), two different
heights and three different widths. The range includes also head cabinets for the completion of
back-to-back runs as well. The cabinet is appropriate for the preservation and self-service sale
of fresh and/or pre-packed products. Its main features and dimensions are clearly illustrated in
dra-wings 1, 2, 3, 4 on page 23-25. As for its weights, crating included and excluded, see table
I on page 25. A wide variety of optional accessories enabling enhanced functions is also
available. To this respect, contact the authorised after-sales service only.
2. TRANSPORTATION
The display cabinet is contained in a specially crated package that enables transportation by the
use of fork-lift trucks. Handle the machine on its own pallet or on a similar platform; use a fork
lift, either manual or electric, provided it is adequate for handling such appliances and it has the
requisite lifting capacity (see page 25 - fig. 3 - 4 and table I).
3. DELIVERY AND STORAGE
Prior to accepting the case from the carrier, check the conditions of the package. If it is showing
visible damage, the machine too may have been impaired. In this case, unpack the machine in the
presence of the carrier and sign, though with reservation, the delivery bill. The manufacturer assu-
mes no liability for damage caused by transportation or wrong handling during storage. Unpacking
is reserved for the authorised after-sales service. Storing temperature must be between -25°C and
+55°C, air humidity between 30% and 95%. Keep the cabinet safe from direct sunlight and from
the elements.
4. INSTALLATION AND AMBIENT CONDITIONS
Before connecting the case make sure that its rating plate data correspond to the features of the
existing electrical installation (see page 27 - tab. III). For correct operation, the machine must be
placed on a level floor (see page 26 - fig.5), far from sources of heat and/or direct sunlight, doors,
windows, fans or ventilation outlets (see page 26 - fig.6). It must also be granted a reasonable free
front area for customer service.
5. ELECTRICAL CONNECTION
The position of the cut-out switch must enable its actuation in any emergency situation (maximum
distance 3 m). Show the position of the cut-out switch to any prospective operator.
The refrigerator must be installed by professionally qualified personnel, in accordance with the
instructions provided by the manufacturer and local regulations. Incorrect installation may cause
harm to persons, animals and property. The manufacturer assumes no responsibility for such da-
mage.
A supply cable of type HO5VV-F 1mm² or higher must be used for the main supply.
Make sure that the system power supply voltage corresponds to the values appearing on the rating
plate of the equipment. Consider also that the maximum allowable power voltage variation is +/-
6%.
IMPORTANT: THE EQUIPMENT MUST BE PROPERLY EARTHED. The manufacturer assumes