8Н16А
4-hole socket adapter for the 7H08A hole lock
INSTRUCTIONS FOR USE AND MAINTENANCE
Dear Customer,
Please read the instructions carefully. Make sure that the user understands the instructions
for use, paying particular attention to the safety and maintenance warnings.
APPLICATION
The 4-hole socket adapter is used in the sockets of femoral and tibial prostheses. It serves
to connect the socket to the 7H08A hole lock.
TECHNICAL CHARACTERISTICS
Code
Support material
Liner support weight kg
For patients weighing
Temperature range for use
Warranty period
DESCRIPTION OF THE STRUCTURE
The 4-hole socket adapter consists of support 1 (see Fig. 1) and four screws 2 of 30 mm in
length for connection to the 7H08A hole lock.
The support has been manufactured by machining, ensuring high strength and quality.
1
Support
FITTING THE ITEM TO THE PROSTHESIS
During lamination preparation, the cap, position 4, is fixed (see Fig. 2) with nails 5, to the
plaster mould, position 6. (The heads of the nails, position 5, should not be allowed to pro-
trude from the cap, position 4). The socket support is fitted, position 2, with the fixing screws,
position 3, to the cap, position 4, and fixed with the screw, position 1.
The arrow located on the socket support should be aligned in the anteroposterior direction.
2
4
6
1
Screw
2
Support
3
Fixing screws
4 units
ORLIMAN S. L. U.
C/ Ausias March, 3 - Pol. Ind. La Pobla-L´Eliana · Apdo. de correos 49
C.P.: 46185 - La Pobla de Vallbona Valencia - España (Spain)
Tel.: +34 96 272 57 04 - Fax: +34 96 275 87 00 - Exports Tel.: +34 96 274 23 33
E-mail: orto@orliman.com · Exports email: export@orliman.com - www.orliman.com
LB-I-8H16A
EDITION: 05/2015
8Н16А
Aluminium
0.09
up to 125 kg
From -40°C to +40°C
3 years
2
1 unit
М6 screw, 30 mm
1
3
5
4
1 unit
Cap
5
1 unit
Nails
6
Plaster mould
The base, position 2, is fitted to the socket by lamination. After lamination, remove the re-
maining resin to the surface of the screws, forming a flat support platform.
Remove the fixing screws, position 3, the screw, position 1, and the cap, position 4 (Fig. 2).
The 7H08A hole lock, position 3, connects to the support with the socket, position 1 (see Fig.
3) using 4 screws, position 4. The tightening torque can be obtained from the Instructions
for Use for the 7Н08А.
1
Socket
2
Socket
RECOMMENDATIONS - WARNINGS
These products should not be used for purposes other than those described in these instruc-
tions. They should only be used by one person and under the conditions prescribed.
Before use, the product must be adapted by an orthopaedic technician.
When disposing of the product and packaging, strictly comply with the refuse disposal reg-
ulations of your community.
In knee joints, there is risk of entrapment, use caution.
As the product features metal components, use caution in the case of magnetic resonance.
WARRANTY
4 units
These products comply with European Medical Devices Directive 93/42/EEC (Spanish Royal
Decree 1591/2009). They have undergone tests in accordance with international standard
EN ISO 22523 for prostheses and orthoses and EN ISO 10328 for lower-limb prostheses.
ORLIMAN, S.L.U. guarantees all of its products, provided that they have not been tampered
with or altered from their original form. The company does not guarantee products whose
characteristics have been altered through any kind of misuse, breakage or defect. If you
notice any defect or abnormality, notify the supplier immediately in order for the product
to be replaced.
1 unit
4 units
WARRANTY
years from purchase
Reference
Signature and stamp of the
orthopaedic establishment
1
2
4
3
3
7H08A hole lock
4
Screws
Batch
Date of
no.
purchase
For the warranty to be valid, it is
necessary to complete these details.