technician.
Use only pressurized drinking water for cleaning.

8.1 Cleaning the air system

The finned heat exchanger, ventilator and condensate outflow should be cleaned of contaminants
(leaves, twigs, etc.) before each new heating period. These types of contaminants can be manually
removed using compressed air or by flushing with clean water.
It may be necessary to remove the device cover and air inlet grid first.
Attention: Before opening the device, ensure that all circuits are isolated from the power supply.
To prevent the evaporator and the condensate tray from being damaged, do not use hard or sharp
objects for cleaning.
Under extreme weather conditions (e.g. snow drifts), ice may form on the air intake and exhaust air
outlet grids. If this happens, the ice must be removed in the vicinity of the air intake and exhaust air
outlet grids to ensure that the minimum air flow rate is maintained.

8.3 Winter Shutdown/Lay-up

If there is a chance of frost after the bathing-season has ended when the swimming pool heating is
switched off and the external temperature is expected to drop below the operating limit, the water
circuit of the heat pump should be completely drained. Otherwise, suitable constructional measures
should be taken by the customer to protect the heat pump against damage from frost.
Attention: The warranty does not cover damage caused by inadequate lay-up measures during the
winter.

9. TROUBLESHOOTING

This section provides useful information for diagnosing and correcting certain troubles which may occur.
Before starting the troubleshooting procedure, carry out a thorough visual inspection of the unit and look
for obvious defects such as loose connections or defective wiring.
Before contacting your local dealer, read this chapter carefully, it will save you time and money.
WHEN CARRYING OUT AN INSPECTION ON THE SWITCH BOX OF THE UNIT, ALWAYS MAKE SURE THAT
THE MAIN SWITCH OF THE UNIT IS SWITCHED 'OFF'.
The guidelines below might help to solve your problem. If you cannot solve the problem, consult your
installer/local dealer.
The heat pump will not run.
Please check whether: