OTHER IMPORTANT MESSAGES THAT APPEAR ON THE SCALE

This message indicates that a weight that exceeds the maximum capacity has been placed on the
scale. To correct it simply, remove the over weight.
This message appears in two different situations:
a) When the scale is turned on with an excessive weight on the plate (near to the half capacity of
the scale). To correct this situation remove the weight that is on the scale, turn off the scale, and
then turn it on again.
b) When the scale was handled roughly and/or got hitted during the shipment, wich caused
irreversible damages in its operation. In this case call your authorized distributor.
This message indicates a negative weight, this could happen if you lift or remove the scales plate to
correct this put the plate back in its place and press the
it on again.
This message appears when:
If we turn on the scale with a product on the plate, to eliminate this message simply remove the
product that is on the scale, turn off the scale and then turn it on again.