Before you call for service to your authorized distributor because of a malfunction in your scale, we
suggest you first check this manual again to avoid a misunderstanding of the operation and use of
the functions. If everything is correct, then try to correct the problem according to the following list
since a simple checkup or a small adjustment could eliminate it. If you do not find the problem,
contact your authorized distributor.
Problem
It does not operate.
The scale shows different
weights when the same
product
is
weighed
several times.
The
message
UnLOAD" appears in the
view finder.
The
word
"HELP"
appears in the
"PRICE" indicator.
TROUBLESHOOTING
Possible cause
There is not electric current.
AC/DC Power supply cable has
a false contact.
Low battery.
Material under the plate holder
is
obstructing
movement.
"PLS.
The scale was turned on with a
weight on the plate or without
the plate.
The scale was turned on with a
big weight on the plate.
TECHNICAL SPECIFICATIONS
Max. Capacity
Min. Division
Max. Tare
Max. Price
Range of operation temp.
Range of storage temp.
AC/DC
OUTPUT 9 Vd.c. 500 mA.
With a multimeter check if there is
electric current in the outlets.
Check that the AC/DC power supply
terminals, if it is possible, check with
another AC/DC power supply.
Connect the AC/DC power supply if the
scale
battery.
Check that there are not materials
the
correct
under the plate holder. If there are,
remove them and check the operation
again.
Remove the weight or put back the
plate in its place. Turn off the scale
and then turn it on again.
Remove the weight and turn off the
scale and then turn it on again.
20 kg / 35 kg
0.005 kg / 0.010 kg
9.995 kg / 17.50 kg
$999.99
14 to 104 ºF (-10 to 40 ºC)
-4 to 122 ºF (-20 to 50 ºC)
POWER SUPPLY :
APPROVED BY
Solution
operates,
then
recharge
the
ENGLISH
15