Operating Instructions

Operation

5
Operation
Caution
The tyre pressure controller is not
suitable to fill bicycle tyres fitted with
normal bicycle valves and adapter. The
tyres may be overfilled !
Set required tyre pressure via +/- keys
Press the OK button to acknowledge the
setpoint value.
Connect the hose with the tyre valve – the
filling process will start automatically.
A signal will sounded when the setpoint
value is made. The process will be repea-
ted automatically for the following tyres.
In case of completely deflated tyres, press the
OK button a second time.
6

Faults, causes, remedies

Fault message E-1
Cause
Fall short of the minimum supply pressure
(7 bar)
Fault message E-2
Cause
Defect of the pressure transformer
Fault message E-4
Cause
Tyre valve is not open
Filling hose is kinked
Remedy
Check the supply pressure, and set, if and
when necessary ( min. 7 bar ; max. 16 bar )
Remedy
Notify the Service Department
Remedy
Remove valve plug and connect again
Check the filling hose
109493 07/11