8
MEMO
Clock function:
A timer can be connected to the open-close pushbutton in order to keep the gate open at certain times
during the day, after which it reverts to automatic closing.
DIAGNOSTICS LED
DL1
PEDESTRIAN button red LED signal
DL2
OPEN/CLOSE button red LED signal
DL3
ERRORS red LED signal
DL4
STOP button green LED signal
DL5
PHOTOCELL green LED signal
DL6
SENSITIVE EDGE green LED signal
DL7
BATTERY CHARGER green LED signal
K123M CHARACTERISTICS
LED - DL3
The LED, besides indicating that the power supply is connected, also signals errors with a series of
pre-defined flashes:
steady light:
normal operation;
1 flash:
buffer battery voltage lower than 11.3 Vdc;
Check the mains power supply, charge the battery, replace the battery;
2 flashes:
phototest error;
Disable phototest (dip-switch 6 OFF), check operation and connection of photocells;
3 flashes:
power failure;
Check the thermal-magnetic circuit breaker (upstream from system), check the fuses;
4 flashes:
max current limit exceeded;
Gearmotor has exceeded absorption limits, check for obstacles across the path of the gate, check the
current absorption of the motor when loadless and under load;
5 flashes:
absence of encoder signal / no motor signal;
Check wiring, check encoder through TEST-ENCODER (optional);
Check wiring, check that the motor rotates freely when powered directly by battery, check fuse F2;
6 flashes:
presence of obstacle after 5 failed attempts to close;
Make sure there are no obstacles across the path of the gate and that it slides smoothly;
7 flashes:
no memorization procedure has been executed;
Execute memorization procedure.
Multiple errors are signalled by a 2-second pause between signals.
If the encoder is activated 5 consecutive times during the same closing manoeuvre (obstacle detection),
the control unit opens completely. On the next manoeuvre, the control unit will switch to slow-down
mode as it searches for the closing travel limit.
GATE OPEN WARNING LIGHT (18 Vdc - max. 3W)
The gate open warning light flashes during the opening or closing manoeuvre in synchrony with the
flashing light, then shows a steady light when the gate has opened completely. Once the closing ma-
noeuvre has been completed this light goes off .
On
the memorization function is enabled for self-learning of the travel;
leave the dip-switch in this position when the memorization procedure
Off
has been completed.
K123M
17