tau 750D751M Guía Para La Instalación página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Terminals
Function
Description
1 - 2
POWER SUPPLY
POWER input 230Vac, 50Hz, single-phase;
PRIMARY
transformer primary connector
M2
TRANSFORMER
[1 blue wire (230V) + 1 black wire (0V)];
SECONDARY
transformer secondary connector
M5
TRANSFORMER
[1 blue wire (0V) + 1 brown wire (15V) + 1 white wire (24V) + 1 black wire (0V) + 1 red wire (12V)];
3 - 4
FLASHING LIGHT FLASHING LIGHT output 230Vac, 20W max. The signal is already modulated for direct use. Flashing frequency is double during closing;
MOTOR M1 power output (opens the leaf fitted with the electric lock), 230 Vac, max. 300 W.
5 - 6 - 7
MOTOR M1
5=CLOSE, 6=COMMON, 7=OPEN. Notice: connect the capacitor between terminals 5 and 7;
MOTOR M2 power output, 230 Vac, max. 300 W.
8 - 9 - 10
MOTOR M2
8=CLOSE, 9=COMMON, 10=OPEN. Notice: connect the capacitor between terminals 8 and 10;
11 - 12
OPEN/CLOSE
OPEN/CLOSE button input (contact normally open); for operating information see dip-switches 2 and 3 functions (COMMON=11);
N.O. PEDESTRIAN button contact input
11 - 13
PEDESTRIAN
commands total opening and closing of motor 1 – governed by dip-switches 2 and 3 (COMMON=11);
STOP button input (normally closed contact); this stops the automatic system. At the next command, the opposite operation to the previous
11 - 14
STOP
one is performed (COMMON=9);
SENSITIVE EDGE input (fixed edge, dip 10 OFF) or 8,2 KΩ RESISTIVE SENSITIVE EDGE (dip 10 ON), (normally closed contact);
SENSITIVE
15 - 18
Works only when the gate is opening; temporarily stops the gate and partially closes it by about 20 cm in order to allow the obstacle to be
EDGE
removed. (COMMON=18).
PHOTOCELL OR SAFETY DEVICE input INSIDE the gate (Normally Closed contact); COMMON=18.
INTERNAL
16 - 18
When these devices trigger during the opening phase, they temporarily stop the gate until the obstacle has been removed; during the closing
PHOTOCELLS
phase they stop the gate and then totally open it again.
PHOTOCELL OR SAFETY DEVICE input OUTSIDE the gate (Normally Closed contact); COMMON=18.
Then these devices trigger during the closing phase, they stop the gate and then totally open it again.
EXTERNAL
17 - 18
Notice: because the control of the safety system (FOTOTEST) is performed on the photocell's transmitter, this must always be
PHOTOCELLS
powered by terminals 25 – 27, therefore if this connection is broken the control unit will not accept any opening command. To
eliminate the safety system control, position dip-switch 6 to OFF.
19 - 20
ELECTRIC LOCK
ELECTRIC LOCK power output 12 Vac max. 15 W;
2
RADIO CHANNEL output; the output mode can be selected through Dip Switches 7 - 8;
nd
21 - 22
2
nd
RADIO CH
Warning: to connect other devices to the 2nd Radio Channel (area lighting, pumps, etc.), use an additional auxiliary relay.
GATE OPEN
GATE OPEN WARNING LIGHT output; 24 V ac, max 3W; the light lights with the same frequency as that of the flashing light for the entire
23 - 24
WARNING LIGHT
opening and closing manoeuvre and remains on if the gate is open and off when the gate has closed;
24 Vac external transmitting photocell power supply output for safety device control (connect the external TX photocell only)
25 - 27
PHOTOCELL TX
max. of 2 photocell transmitters;
26 - 27
AUX
24Vac output, 10W for the power supply of photocells, external receivers, etc.
28 - 29
AERIAL
AERIAL input (EARTH=28, SIGNAL=29);
LOGIC ADJUSTMENTS
TRIMMER
R. ANTA
second motor delay adjustment: during closing cycle from approx. 0 to 15 sec.; during opening from approx. 0 to 6 sec.
Motor 1 torque adjustment (swing 1).
FR1
The trimmer is set to provide sufficient thrust to work the gate without exceeding the limits established by current standards (EN 12453). Turning the
(T. LAV.)
trimmer clockwise (+) increases the motor torque, turning it anticlockwise (-) reduces it.
Motor 2 torque adjustment (swing 2).
FR2
The trimmer is set to provide sufficient thrust to work the gate without exceeding the limits established by current standards (EN 12453). Turning the
(RALL.)
trimmer clockwise (+) increases the motor torque, turning it anticlockwise (-) reduces it.
CH.AUTO
Automatic closing time adjustment from 2 to 120 seconds.
Notice:
turn the TRIMMER clockwise to increase adjustments; turn it anticlockwise to decrease.
PROGRAMMING INSTRUCTIONS
To adjust the stroke of wings perform the following procedure:
-
fully open both leaves (if a Remote Control has already been programmed it can be used to open the
With DIP SWITCH 4 in ON (Deceleration enabled):
1
press and hold down for at least 5 seconds P1 and P2 buttons to activate the programming mode
2
the DL7 LED will begin blinking fast to confirm that programming mode is active
3
press either AP/CH button or the remote control: the leaf #2 will close at standard speed
4
press either AP/CH button or the remote control when the leaf should start to decelerate
5
when the leaf is completely closed press either AP/CH button or the remote control (leaf #2 programming completed)
6
press either AP/CH button or the remote control: the leaf #1 will close at standard speed
7
press either AP/CH button or the remote control when the leaf should start to decelerate
8
when the leaf is completely closed press either AP/CH button or the remote control (leaf #1 programming completed)
9
the DL7 LED will stop blinking and remain steady ON (programming completed and saved);
With DIP SWITCH 4 in OFF (Deceleration disabled):
1
press and hold down for at least 5 seconds P1 and P2 buttons to activate the programming mode
2
the DL7 LED will begin blinking fast to confirm that programming mode is active
3
press either AP/CH button or the remote control: the leaf #2 will close at standard speed
4
when the leaf is completely closed press either AP/CH button or the remote control (leaf #2 programming completed)
5
press either AP/CH button or the remote control: the leaf #1 will close at standard speed
6
when the leaf is completely closed press either AP/CH button or the remote control (leaf #1 programming completed)
7
the DL7 LED will stop blinking and remain steady ON (programming completed and saved).
Notice:
-
STOP input will stop the programming at any time. The programming mode remains active and can be re-started from point 1
-
while DL7 blinks, press and hold down for at least 5 seconds P1 and P2 buttons to kill exit programming mode
-
set a working time slightly longer than necessary (a couple of seconds) to allow complete opening/closing of the leaves.
DIP SWITCH
On after opening, the gate automatically closes when the delay set on the T.C.A. trimmer expires;
AUTOMATIC
1
CLOSING
Off automatic closing disabled;
with automatic closing enabled, a sequence of open/close commands causes the gate to OPENCLOSE-OPEN-CLOSE etc (see also dip
On
switch 3);
2
2 / 4 STROKE
Off in the same conditions, the same command sequence causes the gate to OPEN-STOP-CLOSE-STOP-OPEN-STOP (step-by-step);
gate);
On the gate ignores the close command while it is opening (NO REVERSE);
3
NO REVERSE
Off the gate behaves according to the position of dip-switch n° 2;
On the deceleration function is on (see "PROGRAMMING INSTRUCTIONS");
4
DECELERATION
Off the deceleration function is off;
On the pre-flashing function enabled;
5
PRE-FLASHING
Off the pre-flashing function disabled;
On the "photocell test" function is enabled;
6
FOTOTEST
Off the "photocell test" function is disabled. N.B.: to be used when the photocells are not used;
7 - 8
2nd RADIO CHANNEL operation (terminals no. 18 - 19)
Dip 7
Dip 8 Function
Gate contact open: The contact activates on opening the gate and remains active during the open time, during the TCA and during reclosure. It
OFF
OFF
deactivates once the gate has completed its closure movement.
OFF
ON
Bistable function active: the radio control impulse causes the contact to activate and remain active until the subsequent impulse.
ON
OFF
Monostable function active for 2 sec.: the radio control impulse causes the contact to activate and remain active for 2 sec.
ON
ON
Monostable function active for 180 sec.: the radio control impulse causes the contact to activate and remain active for 180 sec.
On the "opening ram blow" function is on. This permits the release of the electric lock (to be used only in the presence of an electric lock);
OPENING
9
RAM BLOW
Off the "opening ram blow" function is off;
On RESISTIVE SENSITIVE EDGE (terminal no. 15)
SENSITIVE EDGE
10
SELECTION
Off RESISTIVE EDGE - fixed edge (terminal no. 15)
IMPORTANT:
Each pair of terminals attached to an NC contact that is not in use must be short-circuited in order to ensure the proper operation of the board.
The door's earthing system must comply with current standards. The manufacturer will accept no liability for any damage deriving from failure to comply with this requirement.
433.92 MHz BUILT-IN RADIO RECEIVER
The radio receiver can learn up to a maximum of 30 dip-switches (TXD2, TXD4, BUG2, BUG4, SLIM, SLIM-C,T-4, T-4C) or rolling codes (BUG2R, BUG4R, SLIM-RP, T-4RP)
which can be set on the two channels as required.
The first channel directly commands the control board for opening the automatic device; the second channel commands a relay for a N.O. no-voltage output contact (terminals
21 and 22, max. 24 Vac, 1 A).
The learning mode (dip-switch or rolling code) is determined by the first radio control device and remains unchanged until all the codes have been cancelled.
LEARNING SYSTEM FOR RADIO CONTROL DEVICES
P1 = OPEN/CLOSE
P2 = 2nd channel
1_ press button P1 briefly to associate a radio control device with the OPEN/CLOSE function;
2_ LED DL7 turns off to indicate that the code learning mode has been activated (if no code is entered within 10 seconds, the board exits the programming mode);
3_ press the button of the relative radio control device;
4_ LED DL7 turns on again to indicate that the code has been memorised (if this does not happen, wait 10 seconds and start again from point 1);
5_ to memorise codes to other radio control devices, repeat the procedure from point 1 up to a maximum of 30 transmitters;
6_ to memorise codes on the 2nd channel, repeat the procedure from point 1 using button P2 instead of P1;
7_ to exit the learning mode without memorising a code, press button P1 or P2 briefly.
Notice: if the maximum number of radio control devices (30) is exceeded, LED DL7 flashes rapidly for about 3 seconds without memorising the code.
If equipped with radio controls model SLIM-RP or T-4RP programmed by means of TAU-PROG, they can be memorised without using control unit keys P1 and P2. In this case
refer to the instructions of the specific radio control for the procedure for memorisation via radio.
REMOTE PROGRAMMING BY ROLLING CODE
It is possible to carry out the remote self-learning of rolling code transmitters, that is without pressing the receiver's programming button.
It will be sufficient to have an already programmed transmitter in the receiver in order to start the procedure of remote programming of the new transmitters, programmed by
means of TAUPROG. Follow the procedure written on the instructions of the rolling code transmitter.
CANCELLING CODES FROM RADIO CONTROL DEVICES
1_ keep button P1 pressed for 3 seconds in order to cancel all the associated radio control devices;
2_ LED DL7 flashes slowly to indicate that the cancellation mode has been activated;
3_ press button P1 again for 3 seconds;
4_ LED DL7 turns off for approx. 3 seconds and then remains steady to indicate that the code has been cancelled;
5_ repeat the procedure from point 1 using button P2 to cancel all the associated radio control devices;
6_ to exit the learning mode without memorising a code, press button P1 or P2 briefly.
ATTENTION: TO memorise a code on a new type of remote control unit (e.g.: from dip-switch to rolling code or vice-versa) both channels must be cancelled.
DL7 LED STATUS AND ERROR CODES
2 flashes =
Photo-cell Test Error
7 flashes =
Missing Programming Error
Continuous fast flashes =
Programming Mode Active
MALFUNCTIONS: POSSIBLE CAUSES AND SOLUTION
The automation does not start
a-
Check there is 230Vac power supply with the multimeter;
b-
Check that the NC contacts of the card are actually normally closed (4 green LEDs on);
c-
Set dip 6 (phototest) to OFF;
d-
Check that the fuses are intact with the multimeter.
The radio control has very little range
a-
Check that the ground and the aerial signal connections have not been inverted;
b-
Do not make joints to increase the length of the aerial wire;
c-
Do not install the aerial in a low position or behind walls or pillars;
d-
Check the state of the radio control batteries.
The gate opens the wrong way
Invert the motor connections on the terminal block (terminals 5 and 7 for motor 1; terminals 8 and 10 for motor 2);

Publicidad