D751M
Control panel for two single-phase motors 230 Vac
D_MNL0D751M 29-03-2012 - Rev.02
Introduction
This manual has been especially written for use by qualified fitters. No information given in this manual can be considered as being of interest to end users. This manual is
enclosed with control unit D751M and may therefore not be used for different products!
Important information:
Disconnect the panel from the power supply before opening it.
The D751M control unit has been designed to control an electromechanical gear motor for automating gates and doors of all kinds.
Any other use is considered improper and is consequently forbidden by current laws.
Do not install the unit before you have read all the instructions.
INSTALLATION
Before proceeding, make sure the mechanical components work correctly. Also check that the gear motor assembly has been installed according to the instructions.
NB : it is compulsory to earth the system and to observe the safety regulations that are in force in each country.
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables.
IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE THE PROPER WORKING ORDER OF THE EQUIPMENT AND CREATE HAZARDOUS
SITUATIONS FOR PEOPLE. FOR THIS REASON THE "MANUFACTURER" DECLINES ALL RESPONSIBILITY FOR ANY MALFUNCTIONING AND DAMAGES THUS
RESULTING.
CONTROL CARD FOR TWO SINGLE-PHASE MOTORS 230 Vac
The D751M panel features an electronic photocell control system which switches the external photocell transmitter on and off thereby causing the control unit microprocessor
to check whether the relay switches correctly. If this does not happen, the control unit is automatically blocked
MICROPROCESSOR-CONTROLLED LOGIC
SELF-DIAGNOSIS LED's
LINE INPUT FUSE
BUILT-IN TORQUE LIMITING DEVICE
ELECTRONIC CONTROL OF SAFETY DEVICES
PEDESTRIAN ENTRY FUNCTION
BUILT-IN FLASHING LIGHT CIRCUIT
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
"SLOW-DOWN" FUNCTION IN OPENING AND IN CLOSING PHASE
TESTING
When all connections have been made:
All the green LS LED's must be on (each corresponds to a Normally Closed input).
They only turn off when the commands they are associated with are active.
All the red LS LED's must be off (each corresponds to a Normally Open input) they only turn on when the commands they are associated with are active.

TECHNICAL CHARACTERISTICS

Power input to board
230Vac - 50Hz
Max motors nominal power
600 W ca.
Primary input line rapid fuse (F1 - 5x20)
F 6,3 A
Input voltage of motor circuits
230 Vac
Input voltage of auxiliary circuits
24 Vac
24Vac line rapid fuse (F2 - 5x20)
F 1,6 A
Logic circuit input voltage
5 Vdc
Working temperature
-20°C ÷ + 70 °C
Box protected to
IP43
DIAGNOSTICS LED
DL1
OPEN/CLOSE button red LED signal
DL2
PEDESTRIAN button red LED signal
DL3
STOP button green LED signal
DL4
SENSITIVE EDGE green LED signal
DL5
INTERNAL PHOTOCELL green LED signal
DL6
EXTERNAL PHOTOCELL green LED signal
DL7
RADIO CONTROLS programming and ERRORS red LED signal
TERMINAL BOARD CONNECTIONS
Key:
N.C. =
Normally Closed
N.O. =
Normally Open