Handling; Product Setup; Requirements - Thermor IAC/S 300 Instrucciones De Instalacion Y De Uso

Interacumulador de agua caliente sanitaria
Ocultar thumbs Ver también para IAC/S 300:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Product Overview
3.

Handling

The product includes several handles to facilitate carrying to the installation site.
Tilt the product backward for handling with a hand trolley, for example.
To transport the water heater to the installation site, use lower and upper handles.
Follow transporting and handling requirements indicated on the packaging label of the water heater.
4.

Product Setup

4.1.

Requirements

A drain pan must be installed under the water heater when installed above inhabited dwellings.
Depending on the models, the water heaters can be wall mounted or placed on the floor.
The wall-hung vertical models are fitted with brackets allowing direct fastening to 4 bolts to be secured on the wall.
In upright position, if the wall cannot support the weight of the device filled with water, put it on a tripod (optional) and
secure it to the wall using the top bracket.
Leave a clearance of 500 mm below the protective cover (see diagram below) to allow access for equipment
maintenance or possible disassembly.
A drain connected to the sewer is required at the outlet of the safety unit.
Réf doc : U0570659_#
Installation
Operation
Maintenance and
Troubleshooting
Warranty
Page 15/ 220

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Iac/s 150Iac/s 200

Tabla de contenido