Remedy Of Faults; Wear Parts; Guarantee Conditions - Pontec PondoVario Serie Instrucciones De Uso

Ocultar thumbs Ver también para PondoVario Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20

Remedy of faults

Malfunction
The unit is not operating
Insufficient delivery rate
Unit switches off after a short running period

Wear parts

The impeller unit is a wearing part and does not fall under the warranty.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
 Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
 Isolate the unit before starting any work.
 Secure the unit to prevent unintentional switching on.
Note!
Recommendation on regular cleaning:
 Clean the pump as required but at least twice a year.
 Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
 Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
 After cleaning, thoroughly rinse all parts in clean water.
Cleaning the pump
How to proceed:
 G
1. Unscrew the transition piece (with telescopic extension or stepped hose adapter) from the pump.
2. Actuate the engagement hooks on the filter housing and open the filter housing.
3. Unscrew the pump lid by turning counter-clockwise and remove (bayonet closure).
4. Pull out the impeller unit (magnetic resistance).
5. Rinse all parts.
6. Reassemble the unit in the reverse order.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean the unit, check for damage and
store immersed in water in a frost-free environment. Do not immerse the plug!
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.

Guarantee conditions

PfG grants a 3 year guarantee from the date of sale on proven material and manufacturing faults. Prerequisite for our
guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused,
electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs
are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defec-
tive unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the
right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier.
Further claims of whatever type, especially consequential damage, are excluded. This guarantee does not affect the
final customer's claims against the dealer.
Cause
No mains voltage
Impeller blocked
Strainer casing clogged
Excessive pressure losses in the hoses
Water temperature too high
Remedy
Check mains voltage
Clean impeller
Clean strainer casing
Reduce hose length and connecting parts to a
minimum, route hoses as straight as possible
Note maximum water temperature of +35 °C
- EN -
11

Publicidad

Tabla de contenido
loading

Tabla de contenido