Special Features– Laser Detector
The LCD display of the detector LD400G has seven distinct channels of information, indicating the
position of the detector in the plane of laser light, as indicated in (Fig. 3).
As you move the detector closer to the center, the arrows fill in to indicate the laser position.
The detector has a unique memory feature, which preserves the last position of the laser beam if
the detector is moved out of the plane of laser light, as well as built in electronic filtering for bright
sunlight and electromagnetic interference.
The detector LD400G has three speaker selections (Off, Loud (105dBA) and Louder (125+ dBA)), .
Care of Your Universal Laser Detector
This instrument is gasket sealed for water and dust protection. Use a soft, dry cloth to remove any
dirt or moisture from the instrument before storage. Do not use benzene, paint thinner, or other
solvents to clean the instrument. Remove battery before long-term storage of the instrument.
Specifications
D D e e s s c c r r i i p p t t i i o o n n
L L D D 4 4 0 0 0 0 G G
Dimensions
6.6" H x 3" W x 1" D (169mm x 76mm x 25mm)
Weight
10 oz. (275g)
Range
Up to 1600-ft (488m) Diameter
Fine ± 0.75mm
Beam Resolution *
Medium ±1.5mm
Wide ± 3mm
Readout
LCD, 2 windows
Power
One 9-volt battery provides 3 months of typical usage
Warranty
1 year (For warranty conditions see "Warranty")
* Note: Sensitivity values based on standard conditions with most lasers; may vary slightly due to
make, manufacturer, beam size, or working conditions.
Subject to change without notice
4 • LD400G