- AB620A5035

7.22 Funciones FlipFlop (AFF)

Función
FlipFlop 1
Asignación de salida
F-830 =0
AFF1 = apagado (valor
preajustado)
F-830 =1
AFF1 =M1
F-830 =2
AFF1 =M2
F-830 =3
AFF1 =M3
F-830 =4
AFF1 =M4
F-830 =5
AFF1 =M5
F-830 = 6
AFF1 = M6
F-830 = 7
AFF1 = M7
F-830 = 8
AFF1 = M8
F-830 = 9
AFF1 = M9
F-830 = 10
AFF1 = M10
F-830 = 11
AFF1 = M11
Asignación de entrada: F-24x =101
Función
FlipFlop 2
Asignación de salida
F-831 =0
AFF2 = apagado (valor
preajustado)
F-831 =1
AFF2 =M1
F-831 =2
AFF2 =M2
F-831 =3
AFF2 =M3
F-831 =4
AFF2 =M4
F-831 =5
AFF2 =M5
F-831 = 6
AFF2 = M6
F-831 = 7
AFF2 = M7
F-831 = 8
AFF2 = M8
F-831 = 9
AFF2 = M9
F-831 = 10
AFF2 = M10
F-831 = 11
AFF2 = M11
Asignación de entrada: F-24x =102
Función
FlipFlop 3
Asignación de salida
F-832 =0
AFF3 = apagado (valor
preajustado)
F-832 =1
AFF3 =M1
F-832 =2
AFF3 =M2
F-832 =3
AFF3 =M3
F-832 =4
AFF3 =M4
F-832 =5
AFF3 =M5
F-832 = 6
AFF3 = M6
F-832 = 7
AFF3 = M7
F-832 = 8
AFF3 = M8
F-832 = 9
AFF3 = M9
F-832 = 10
AFF3 = M10
F-832 = 11
AFF3 = M11
Asignación de entrada: F-24x =103
- 42 -
Conexiones
F-038 =0
Conexión apagada (valor preajustado)
F-038 =1
Conexión con FSPL
F-038 =2
Conexión con cambio de elevación
F-038 =3
Conexión con FSPL y cambio de elevación
Conexión apagada (valor preajustado)
F-039 =0
Conexión con elevación del prensatelas (en la
F-039 =1
costura)
Conexión con elevación del prensatelas (al
F-039 =2
final de la costura)
Conexión con elevación del prensatelas (en y
F-039 =3
al final la costura)
Conexiones
F-040 =0
Conexión apagada (valor preajustado)
F-040 =1
AFF3 apagado cuando la elevación del
prensatelas está activada
F-040 =2
AFF3 apagado cuando el remate está
activado
F-040 =3
AFF3 apagado cuando el remate o la
elevación del prensatelas están activado
Manual de instrucciones
Parámetro
(AFF1)
830
Parámetro
(AFF2)
831
Parámetro
(AFF3)
832