RAC 172
SIGNALS
- Does not fasten the rivet
- Oil leak
- Air leak
- Not ejected nail
GB
TROUBLE SHOOTING
CAUSE
- Non-powered tool
- Slipping of the clamps on the nail - Perform clamps maintenance
- Lack of oil
- Incorrect nozzle
- Unfiltered and unlubricated air
- Worn gaskets
- Oil filler cap not tightened
- Incorrect positioning of the
feeding tube
- Worn gaskets
- Breaks on the riveting machine
body
- Incorrect nozzle
- Closed suction system
- Full nails container
75036036 - RAC172 – rev 02 - ( 04-2019 )
SOLUTIONS
- Connect the riveting tools to the
compressed air
- Top up oil
- Replace the nozzle as shown in
the table
- Equip yourself with lubricator
filter assembly
- Contact the service center
- Tighten correctly
- Position the feeding tube correctly
- Contact the service center
- Contact the service center
- Replace the nozzle as shown
in the table
- Open the suction system
- Empty the container