Electrical Connections - Lamborghini Caloreclima NINFA 24 MCS Instrucciones De Uso, Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 92

2.5 Electrical connections

Connection to the electrical grid
B
The unit's electrical safety is only guaranteed when correctly connected to an efficient earthing system exe-
cuted according to current safety standards. Have the efficiency and suitability of the earthing system checked
by professionally qualified personnel. The manufacturer is not responsible for any damage caused by failure
to earth the system. Also make sure that the electrical system is adequate for the maximum power absorbed
by the unit, as specified on the boiler dataplate.
The boiler is prewired and provided with a Y-cable and plug for connection to the electricity line. The connections to the
grid must be made with a permanent connection and equipped with a bipolar switch whose contacts have a minimum
opening of at least 3 mm, interposing fuses of max. 3A between the boiler and the line. It is important to respect the
polarities (LINE: brown wire / NEUTRAL: blue wire / EARTH: yellow-green wire) in making connections to the electrical
line. During installation or when changing the power cable, the earth wire must be left 2 cm longer than the others.
B
The user must never change the unit's power cable. If the cable gets damaged, switch off the unit and have it
changed solely by professionally qualified personnel. If changing the electric power cable, use solely "HAR
H05 VV-F" 3x0.75 mm2 cable with a maximum outside diameter of 8 mm.
Room thermostat (optional)
B
IMPORTANT: THE ROOM THERMOSTAT MUST HAVE VOLTAGE-FREE CONTACTS. CONNECTING 230
V TO THE ROOM THERMOSTAT TERMINALS WILL PERMANENTLY DAMAGE THE ELECTRONIC
BOARD.
When connecting time controls or a timer, do not take the power supply for these devices from their breaking
contacts Their power supply must be by means of direct connection from the mains or with batteries, depend-
ing on the kind of device.
Accessing the electrical terminal board
The terminal board is located at the bottom of the boiler and can be accessed after removing the protection grille (see
fig. 20)
1-2
External sensor
3-4
Room thermostat / Remote timer control (Opentherm)
44
°C
SENSOR
1 2 3 4
1
2
3
4
°C
SENSOR
1 2 3 4
fig. 20 - Accessing the terminal board
cod. 3540F611 - 05/2007 (Rev. 00)
NINFA 24 MCS
GB

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido