Fume Pipes - Lamborghini Caloreclima NINFA 24 MCS Instrucciones De Uso, Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 92
NINFA 24 MCS

2.6 Fume pipes

Instructions
This unit is a "C type" with sealed chamber and forced draught, the air inlet and fume exhaust must be connected to
one of the exhaust/inlet systems indicated below. Before proceeding with installation, make sure the fume pipes do not
exceed the maximum permissible lengths.
B
This C-type unit must be installed using the inlet and fume exhaust pipes supplied by the manufacturer in ac-
cordance with UNI-CIG 7129/92. Failure to use them automatically invalidates any warranty and liability of the
manufacturer.
Diaphragms
Boiler operation requires the diaphragms supplied with the unit to be fitted according to the indications given in the fol-
lowing tables and diagrams.
Choice of diaphragm using coaxial pipes
Type
Coaxial 60/100
Choice of diaphragm using separate pipes
Pipe length calculated in linear metres
Min.
0 m
20 m
To replace the diaphragm:
A - Diaphragm for coaxial pipes
Insert the diaphragm on the Ø60 aluminium pipe section of the top flange on the boiler
B - Diaphragm for separate pipes
Insert the diaphragm under the air inlet Ø80 flanged pipe section
GB
Length up to:
1 bend + 1 metre
1 bend + 3 metre
Max.
20 m
35 m
fig. 21 - Replacing the diaphragm
cod. 3540F611 - 05/2007 (Rev. 00)
Diaphragm to use
Ø 84 external
No diaphragm
Diaphragm to use
Ø 50 internal
No diaphragm
A
B
45

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido