Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

• Turn on the main light breaker (A, Figure 19) (if set to
OFF).
• Turn on individual light switches (B, Figure 19) (1 - 4, if
set to OFF).
The breaker / switches may also be used if manual and indi-
vidual light control is desired.
Turning The Lights Off
The tower lights will automatically turn off when the engine is
shut down. (There is a 0.3-second delay built into the electri-
cal system to protect the capacitors.) If desired, however, the
lights can be turned off without shutting the engine down:
• To turn off individual lights, turn indiviual light switches
(1-4) to OFF.
• To turn off all lights, turn the main light breaker to OFF.
A
Figure 19
Auxiliary AC Outlets
The control panel is equipped with a standard GFCI outlet (A,
Figure 20) and an optional Twistlock outlet (B).
Power is supplied to the outlet(s) only when the engine is
running and the main circuit breaker (C, Figure 20) is in the
ON position.
NOTE: The electrical system is designed with a 20-second
delay after the engine starts before the lights and auxiliary
AC outlet(s) will operate.
Each outlet is protected by a dedicated circuit breaker: 20
amp for GFCI (D, Figure 20), 30 amp for Twistlock (E).
If a breaker trips
1. Disconnect the load from the outlet.
2. Turn off the tower lights or shut down the engine.
3. Wait 10 minutes for the generator to cool down.
4. Correct the load problem.
5. Start the engine or turn on the tower lights.
6. Reset the breaker.
NOTE: Be sure to also check the GFCI breaker on the
GFCI outlet, and reset if necessary.
7. Reconnect the load.
8. If the problem persists, see Troubleshooting.
B
C
E
B
Figure 20
Uni t Shutdown
Once lighting operations are complete at the work site, per-
form unit shutdown:
1. Shut down the engine / tower lights. See Engine
Operation.
2. Wait 10 minutes for the lights to cool.
3. Lower the light tower. See Raising And Lowering The
Light Tower.
4. Rotate the light tower to the transport position. See
Adjusting The Lights.
5. Adjust the light fixtures to the transport position. See
Adjusting The Lights.
6. Remove and store the ground rod. See Ground Rod.
7. Make sure the engine cover is closed and latched.
8. Retract the outriggers. See Leveling And Stabilizing
The Light Tower Trailer.
The unit is now ready for transport. See Transporting.
WARNING
• Do not remove the wheel chocks from the front and
back of the wheels until the light tower trailer is ready
to be transported. Doing so could result in death or
serious injury.

Maintenance

Before performing any maintenance procedures, read Safety.
Proper maintenance and care of the equipment is a must for
safe and reliable operation. Use the following maintenance
and care guidelines in addition to those scheduled by your
shop equipment maintenance schedule.
Where equipment is operated under severe conditions (very
dusty, extreme heat or cold, etc.), affected items should be
serviced more frequently.
D
A
21
en

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido