The top glass VS (TG) and the light-shielding glass panel VL (LG) are fixed to
the range hood's body with magnets. In case of detachment of VS VL (LG)
from the range hood's body due to accidental causes, check its wholeness
and position it back in its place. Otherwise, call technical assistance.
B

TECHNICAL SPECIFICATIONS

The technical data pertaining to the electric appliance The technical specifica-
tions of the appliance are shown on the rating plates located inside the range
hood.
C
INSTALLATION
(Section reserved for qualified installers of the range hood)
Respect the instructions described in Ill. 1-2 for installation.
If the instructions of the gas cooker specify a greater distance, this must be
taken into account. Use a cooker with a maximum thermal power of 12 kW.
In the outside exhaust version, the diameter of the fume discharge duct must
be no smaller than the range hood connection.
In the horizontal sections, the duct must slope slightly (around 10%) upwards,
so at to better convey the air outside of the room.
Reduce curves to the bare minimum, and check that the length of the ducts is
also the bare minimum.
Comply with the current regulations on air discharge into the atmosphere.
If other appliances that use gas or other fuels are being used at the same
time (boiler, stove, fireplace, etc.) make sure the room where the fumes are
extracted is well ventilated, in compliance with the current regulations.
Assembly instructions: see section "O" of the booklet.
D

ELECTRICAL CONNECTIONS

(Section reserved for qualified installers)
WARNING!
Before doing any work inside the range hood, disconnect the appliance from
the mains power supply.
Check that the wires inside the range hood are not disconnected or cut; if this
is the case, contact your nearest service centre. The electrical connections
must be performed by qualified personnel.
The connections must be performed in compliance with the legal standards in
force. Check that the relief valve and the electrical system are able to support
the load of the appliance (see the technical specifications in point B).
Some types of appliance are supplied with a cable without plug; in this case,
"standardised" plugs must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
- the blue wire must be used for the neutral,
- the brown wire must be used for the phase; the cable must not come into
contact with hot parts (over 70°C).
- fit a plug that is suitable for the load to the power cable, and connect it to a
suitable power outlet.