Technical Specifications; Electrical Connections - FALMEC MOVE 120 Manual De Instrucciones

Ocultar thumbs Ver también para MOVE 120:
Tabla de contenido

Publicidad

Check deep-fryers during use: superheated oil may be flammable.
- Ensure there is adequate ventilation of the room when the rangehood is used at the same
time as appliances burning gas or other fuels.
- Do not flambe under the rangehood
- The exhaust air must not be discharged into a flue which is used for exhausting fumes from
appliances burning gas or other fuels.
- Ensure that all regulations concerning the discharge of exhaust air have been fulfilled before
you use the appliance.
Before performing any cleaning or maintenance operations, disconnect the appliance by un-
plugging it or using the main switch. The manufacturer disclaims all liability for any damage
that may be directly or indirectly caused to people, things and animals due to the failure to
follow all the instructions provided in this booklet and above all the warnings relating to the
installation, operation and maintenance of the appliance.
- there is a fire risk if cleaning is not carried out in accordance with the instructions.
CAUTION: Accessible parts may become hot when used with cooking appliances.
- Max. length screw for fixing the chimney is 10 mm (provided by the manufacturer).
WARNING: Failure to install the screws or fixing device in accordance with these instructions
may result in electrical hazards.
Warning only for Australia: hood width less than 90 cm: use max. 4 hobs
B

TECHNICAL SPECIFICATIONS

The technical data pertaining to the electric appliance The technical specifications of the ap-
pliance are shown on the rating plates located inside the range hood.
C
INSTALLATION
(Section reserved for qualified installers of the range hood)
Minimum distance: distance between the highest part of the cooker and the lowest part of the
hood. Generally, when the hood is placed on gas cookers, this distance must be at least of 65
cm (see figure 02). However, according to an interpretation of standard EN60335-2-31 dated
11-07-2002 of TC61 (sub-clause 7.12.1 meeting 15 agenda item 10.11), the minimum distance
between the cooker and the lower part of this hood can be reduced to 55 cm. Should the
instructions for the gas cooker specify a greater distance, take this into consideration.
In the exhaust version, the diameter of the fume discharge duct must not be smaller than the
hood connection. In the horizontal sections, the duct must slope upwards slightly (around 10%)
to better convey the air outside.
Reduce bends to a minimum and make sure the pipes feature the minimum required length.
Comply with the current regulations applying to air discharge into the atmosphere. If other ap-
pliances that use gas or other fuels are being used at the same time (boiler, stove, fireplaces,
etc.), make sure the room where the fumes are extracted is well ventilated, in compliance with
the current regulations. Assembly instructions: see section "O" of this manual.
D

ELECTRICAL CONNECTIONS

(Section reserved for qualified installers)
WARNING!
Before doing any work inside the range hood, disconnect the appliance from the mains
power supply.
Check that the wires inside the range hood are not disconnected or cut; if this is the case,
17 17