5 USE INSTRUCTIONS
1 Power Supply
After making all connections to the terminal board, remember to short-circuit, whenever needed, any unused input (see "connection to the
control board") and power the card: on the display you will read for a few seconds "rES-" followed by the symbol "- - - -" which stands for gate
closed.
2 Visualisation of inputs status
By pressing the "OK" key when the control board awaits further
instructions ("- - - -") the display shows some vertical segments:
each one of them is associated to one of the control board
inputs. When the segment is lighted it means that the contact
associated to it is closed, on the contrary, when it is not lighted
the contact is open.
WARNING During the programming of motor stroke, the control board detects automatically the presence and type of photocells, safety
devices and limit switches installed. It is therefore essential that during this phase all above devices are properly connected and in ope-
ration.
WARNING BEFORE STARTING THE PROGRAMMING OF MOTOR STROKE, IT IS RECOMMENDED TO SELECT THE TYPE OF OPERATOR YOU
INTEND TO USE: PARAMETER P034=0 OPERATOR WITH ENCODER; P034=1 OPERATOR WITHOUT ENCODER.
3 Motor stroke learning
3.1 Door/gate positioning
Instructions
1. Scroll down the parameters until you visualize procedure P001
2. Confirm! The control board is ready for the positioning of the gate/door
3. Position gate/door in its standstill position after opening
4. Confirm! The control board has memorized the gate/door position
3.2 Motor stroke learning
Instructions
1. Scroll down the parameters until you visualize procedure P003
2. Confirm! The control board awaits a further confirmation
3. Confirm by pressing on the OK key for a few seconds! The procedure starts
Now the gate/door starts to close at a slow speed until it reaches the stroke end while closing (or the
4.
limit switch).
5. On the display you will read "- - - -". Motor stroke memorization done!
WARNING If during the door opening you have no access to the push buttons of the control board, you may configure and memorize the
stroke by using the buttons of a 4-channel remote control stored in memory.
3.3 Door/gate positioning and Motor stroke memorization
Instructions
1. Scroll down the parameters until you visualize procedure P001
2. Confirm! The control board is ready for the positioning of the gate/door
3. Position gate/door in its standstill position after opening
Confirm! Now the gate/door starts to close at a slow speed until it reaches the stroke end while clo-
4.
sing (or the limit switch).
5. On the display you will read "- - - -". Motor stroke memorization done!
By pushing the
button the gate must open, by pushing the
1
swap the two motor cables (clamps 4 and 5) and give power supply to the control board again. Only in case you use limit switches, first of all position the
gate where you want it to stop in closing and then adjust the closing cam so that it presses on the closing limit switch in that point. Then position the gate in
the opening position and adjust the opening cam so that it presses on the opening limit switch in that point.
Function
1
Function
Function
1
button the gate must close. If this does not happen, you must turn the control board off,
Display
Display
Display
13