24 V
24 V
3-4
24 V
24 V Batt
5-6
Free contact max. capacity 5 A : this contact can be used to control an open gate
warning light (P27=0) or a courtesy lamp (P27≠0)
LC/SCA
Flashing light output 24 V
7-8
not demand the use of a flashing light card.
LAMP
9
Common safety devices / Connection of motors metallic parts
COM
9-10
+24 V
To be used as power supply of any auxiliary devices, photocell receivers (in all cases),
+24VAUX
and of safety devices when testing these latter before each operation
9-11
+24 V
supply of photocell transmitters (in all cases) and of safety devices when testing these
+24VSIC
latter before each operation
Motor output 24 V
M
12-13
14
N.C. input limit switch while opening. If unused, short circuit to terminal n° 21
FCA
15
N.C. input limit switch while closing. If unused, short circuit to terminal n° 21
FCC
16
N.O. open input. If activated, it opens or closes both motors. It can work in "reversal"
START
mode (P25=0) or "step-by-step" mode (P25=1)
17
N.O. pedestrian opening input. If activated, it opens the motor
PEDON
18
N.C. stop input. If activated, it stops the movement of both motors during any opera-
STOP
tion. If unused, short circuit to terminal n° 21
19
N.C. Photocell input. In case of activation it reverses the movement only while closing
(P26=0) or it reverses the movement while closing and stops while opening (P26=1).
FOTOC
If unused, short circuit to the terminal n°21
20
N.C. leaf safety device input. In case of activation it reverses the movement (P18=0) or
it stops it (P18=1). If unused, short circuit to the terminal n°21
SIC
21
Common inputs
COM
22
Aerial ground input
Aerial signal input
23

8 USE INSTRUCTIONS

After making all connections to the terminal board, remember to short-circuit, whenever needed, any
unused input (see "connection to the control board") and power the card: on the display you will read for
a few seconds "rES-" followed by the symbol "----" which stands for gate closed.
8.1 Visualisation of inputs status
Press on the "OK" key to check if all inputs have been properly connected.
8.2
Setup and memorization of motor stroke
WARNING During motors stroke memorisation, the control board detects automatically the presen-
ce and type of photocells, safety devices and limit switches which are installed. It is therefore essential
that during this phase the latter be properly connected and working.
Table 1 Terminal board connection
transformer power supply input
battery power supply input (Follow carefully polarity indications)
max 15W art. Lumy 24S The intermittent output does
power supply output for auxiliary circuits and uncontrolled safety devices
power supply output for controlled safety devices. To be used as power
max 70W
By pressing the " OK " key when the control board awaits
further instructions ("- - - -") the display shows some vertical
segments: each one of them is associated to one of the con-
trol board inputs (see the picture above). When the segment
is lighted it means that the contact associated to it is closed,
on the contrary, when it is not lighted the contact is open. In
order to do this:
Operating instructions and warnings