Maintenance
4.6 — Long Term Storage
1.
Drain oil from crankcase after the engine cools down. Refill with
recommended grade.
2.
Remove spark plug and pour about 1/2 ounce (15 ml) of engine
oil into the cylinder. Cover spark plug hole with rag. Pull the recoil
starter a couple times to lubricate the piston rings and cylinder
bore. A fogging agent can be used in place of oil.
*
Avoid spray from spark plug hole when cranking engine.
3.
Install and tighten spark plug. Do not connect spark plug wire.
4.
Clean the generator outer surfaces. Check that cooling air slots
and openings on generator are open and unobstructed.
5.
Store the unit in a clean, dry place.
4.7 — Other Storage Tips
• If possible, store the unit indoors and cover it to give protection
from dust and dirt. BE SURE TO CLOSE THE VALVE ON THE
FUEL TANK.
• Cover the unit with a suitable protective cover that does not retain
moisture.
*
NEVER cover the generator while engine and exhaust
areas are warm.
16
5,500 Watt LP Series Portable Generator