13.2) TABLE "B" - LOGIC MENU - (logic)
Logic
Default Defnition
Automatic Closing
OFF
TCA
Time
Opening Impulse
OFF
Ibl open
lock
OFF
Impulse lock TCA
ibl TCA
OFF
3 step
3 step
OFF
Pre-alarm
preal
OFF
Deadman
hold to run
Photocells
OFF
Photoc. open
during opening
OFF
Photocell test
test phot
Safety edge
OFF
test bar
testing
OFF
Master/slave
ster
OFF
Fixed code
fixed code
Remote control
ON
radio prog
programming
Gate open light or
OFF
SCA 2Ch
2nd radio channel
START - CLOSE
start -
OFF
setting
close
OFF
Reversing motion
change
ot.
ICE
OFF
ICE
(special dip 2*)
*=Refer for universal handheld programmer.
13.3) TABLE C: RADIO MENU (RADIO)
Description
Logic
Add Start Key associates the desired key with the Start command.
Add start
Add 2ch Key associates the desired key with the 2nd radio channel command.
add 2ch
Erase List WARNING! Erases all memorized remote controls from the receiver's memory.
erase 64
Read receiver code Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the
W LINK remote control is last pressed.
OFF= W LINK programming disabled.
INSTALLATION MANUAL
Cross out
Description
setting
used
Activates automatic closing
ON
Excludes automatic closing
OFF
The Start impulse has no efect during the opening phase.
ON
The Start impulse becomes efective during the opening phase.
OFF
ON
The Start impulse has no efect during the TCA dwell period.
OFF
The Start impulse becomes efective during the TCA dwell period.
ON
Switches to 3-step logic.
OFF
Switches to 4-step logic.
ON
The fashing light comes on approx. 3 seconds before the motors start.
OFF
The fashing light comes on at the same time as the motors start.
Hold-to-run operation: the manoeuvre continues as long as the OPEN and CLOSE
ON
control keys are kept pressed. The radio transmitter cannot be used.
OFF
Normal impulse operation.
When beam is broken, operation of the photocell is switched of during opening. During closing,
ON
movement is reversed immediately.
When beam is broken, photocells are active during both opening and closing. When beam is broken
OFF
during closing, movement is reversed only once the photocell is cleared.
ON
Switches photocell testing on
Switches photocell testing of
OFF
If disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not equipped
with supplementary test contacts.
ON
Switches safety edge testing on.
Switches safety edge testing of
OFF
If disabled (OFF), it inhibits the safety edge testing function, enabling connection of devices not equip-
ped with supplementary test contacts.
ON
Control panel is set up as the Master unit in a centralized serial connection system.
OFF
Control panel is set up as a Slave unit in a centralized serial connection system.
ON
Receiver is confgured for operation in fxed-code mode.
OFF
Receiver is confgured for operation in rolling-code mode.
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
ON
2- Press within 10 secs. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
The receiver exits programming mode after 10 secs.: you can use this time to enter other new tran-
smitters. This mode does not require access to the control panel.
Disables wireless memorizing of transmitters.
OFF
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
The output between terminals 14-15 is set as Gate open light:
ON
in this case, the 2nd radio channel controls pedestrian opening.
OFF
The output between terminals 14-15 is set as 2nd radio channel.
ON
Input between terminals 21-22 works as CLOSE.
OFF
Input between terminals 21-22 works as START.
ON
Change this parameter if the opening direction needs to be changed
OFF
Standard operating mode.
The controller automatically adjusts the Amperostop safety trip threshold. Check that the force of impact
measured at the points provided for by standard EN 12445 is lower than the value laid down by standard
EN 12453. If in doubt, use auxiliary safety devices. This feature is useful when dealing with installations
ON
running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and
closing cycle.
OFF
The Amperostop safety trip threshold stays at the same set value.
A start impulse has the following efects:
3 steps
closed
opens
on closing
open
closes
on opening
stop + TCA
after stop
opens
4 steps
opens
stop
closes
stop + TCA
opens
23