IPC ECR dual-clean Manual De Instrucciones página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
AIR FILTER.
Check the state of the filter cartridge every 10 hours of ope-
ration; replace the filter every 50 hours of operation or more
frequently if required.
To check and replace, see the engine instructions.
SPARKPLUG.
Check the state of the sparkplug every year or every 100 hours
of operation.
Replace the sparkplug if the electrodes are pitted or burnt or if
the porcelain is damaged. In any case, replace the sparkplug
after 300 hours of operation.
To check and replace, see the engine instructions.
TABLE OF ROUTINE MAINTENANCE TO BE PER-
FORMED BY THE USER
Description of operations:
Check the high pressure hose
and couplings.
1st change H.P. pump / gearbox oil
Subsequent changes H.P. pump /
gearbox oil
Clean the water filter
Check engine oil level
1st engine oil change
Subsequent engine oil changes
Check air filter
Replace filter element
Check sparkplug
Replace sparkplug
The times indicated are for normal operating conditions. For heavy use, reduce the time intervals for each operation.
During maintenance and/or repairs, use original spare parts only as these guarantee greater quality, reliability and
safety characteristics. Failure to use original spare parts absolves the Manufacturer of all liability which passes to
If the hydroblaster is stored for long periods, disconnect it from the mains water supply, empty the tank(s) containing the operating
fluids and make sure parts which might be damaged by dust are protected.
Grease parts which might be damaged by drying out such as the hoses. When preparing for storage, make sure the water supply
hoses are free of cracks or cuts.
Oils and chemical products must be disposed of in accordance with current legislation.
If you decide to stop using the hydroblaster, you should render it unusable by removing the sparkplug.
In addition, parts of the hydroblaster which may represent a hazard, especially for children who may use the decommissioned
equipment to play with, should be rendered harmless. The hydroblaster is classified as special waste and must be dismantled
and divided into similar parts for display in compliance with current legislation.
Do not use components dismantled for scrapping as spare parts.
English
Each use
After 50 hours
Every 500 hours
Every 50 hours
Each use
after 2 hours
every 25 hours or more
frequently with harsh
conditions.
every 10 hours
every 50 hours
every 100 hours
every 300 hours
INFORMATION:
the person responsible for the operation.
STORAGE
SCRAPPING
- 23 -
REPLACING THE HIGH PRESSURE NOZZLE.
Information
The high pressure nozzle on the lance must be replaced regular-
ly as it is exposed to wear during operation. Wear can be identi-
fied by a drop in the working pressure of the hydroblaster.
To replace, contact your supplier and/or dealer for instruc-
tions.
SUMMARY OF EXTRAORDINARY MAINTENANCE
TO BE PERFORMED BY A TECHNICAL SERVICE
CENTRE
Description of operations:
Replace H.P. pump gaskets.
Replace the lance nozzle.
Calibrate and check safety devices.
Every 100 hours
Every 150 hours
Once a year