Other Features - EAS ELECTRIC EHD20DA Manual De Usuario Y Manual De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Auto stop time from 0.0 to 24.
(For control panel E ) Note: Press
seconds to show the room temperature and quit to
show room temperature after 10 seconds.
(For control panel G) Note: The humdity level can not
be set in SHOES and CLOTHES modes.
Display(For control panel G)
Shows the set % humidity level from'CO'to 70% or auto
stop time (0~8) while setting, then shows the actual
( ±5% accuracy) room % humidity level in a range of
30% RH(Relative Humidity) to 90%RH(Relative
Humidity).
Error Codes:
E122-Tube temperature sensor error--Unplug the unit
and plug it back in. If error repeats, call for service;
E142-Room temperature sensor and humidity sensor
error-- Unplug the unit and plug it back in. If error
repeats, call for service;
E163-Main control board fault parameters error--
Unplug the unit and plug it back in. If error
repeats, call for service;
E554-Refrigerant leakage detection-- With this new
technology , the display area will appear'E554'
when the unit detects refrigerant leakage ,call for
service.

Other features

Bucket Full Light
Glows when the bucket is ready to be emptied, or
when the bucket is removed or not replaced in the
proper position.
Auto Defrost
When forst builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
Note: When Auto defrosting operation, the unit may
make a voice of refrigerant flowing, it is normal.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or
when the bucket is removed or not replaced in the
proper position. For some models, the fan motor will
continue to runfor 30 seconds.
Note: Error Codes is displayed HIGH TWO codes (ex. EI )
button for 3
for 1 second, then displayed LOW TWO codes (ex. 22 )
for 1 second circlely.
Display
Shows the set % humidity level from 35% to 85% or
auto start/stop time (0~24) while setting, then shows
the actual(±5% accuracy) room % humidity level in a
range of 30% RH(Relative Humidity) to 90%RH(Relative
Humidity).
Error Codes:
AS-Humidity sensor error--Unplug the unit and plug it
ES-Temperature sensor error-- Unplug the unit and
P2-Bucket is full or bucket is not in right position--
P1-Unit is defrosting--Allow the unit time to
E4-Display panel communication error--Unplug the
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
operation in the first 3 minutes.This is to protect the
unit. Operation will automatically start after 3 minutes.
Auto-Restart
If the unit breaks off unexpectedly due to the power
cut, it will restart with the previous function setting
automatically when the power resumes.
Smart dehumidifying mode(On some models)
At smart dehumidifying mode, the unit will
automatically control room humidity in a comfortable
range 45%~55% according to the room temperature.
The humidity setting function will be invalid.
Anti-mould function(On some models)
Press the Pure pad for 3 seconds to enable this
function. This maximises occupant comfort while
V.1
back in. If error repeats, call for service;
plug it back in. If error repeats, call for service;
Empty the bucket and replace it in the right
position.
automatically service. The protection will clear after
the unit self defrosts. (On some models)
unit and plug it back in. If error repeats, call for
service. (On some models)
Page 15

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ehd30d

Tabla de contenido