Technical Specifications - HQ-Power PS613 Manual Del Usuario

Ocultar thumbs Ver también para PS613:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
1
0 - 30 V "+" output
2
0 - 30 V "-" output
3
current display
4
voltage display
5
12 V "+" output
6
12 V "-" output
5.
Operation
Refer to the illustrations on page 2 of this manual.
When the current limiter indicator [11] lights up, the load is drawing too much current. Reduce the
load.
The values given by the current and voltage displays [3 & 4] are indicative. For accurate readout
please use a calibrated external meter.
0 – 30 V output
1.
Set the voltage knob [9] to the required voltage and the current knob [10] fully counterclockwise.
2.
Switch the power supply on by means of the power button [7] and connect the load.
3.
Turn the current knob [10] clockwise to the required current.
12 V/1 A and 5 V/1 A outputs
These outputs have a fixed voltage and maximum current output; no further adjustment is necessary.
6.
Fuse
Replace a defective fuse only with a fuse of the same type and rating (see Technical Specifications).
In case of a blown fuse: the fuse holder is located at the back of the device. Open it with a
screwdriver, replace the fuse and screw the fuse holder back into place.
7.

Technical Specifications

input voltage
output voltage
output current
limited current
ripple and noise
voltage indicator deviation
current indicator deviation
fuse
working time
dimensions (W x H x D)
weight
protection
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulting from (incorrect) use of this device.
For more info concerning this product and the latest version of this manual, please visit our
website www.hqpower.eu.
The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part
of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise
without the prior written consent of the copyright holder.
V. 02 – 18/11/2013
PS613
7
8
9
10
11
12
230 Vac ± 10 %
0-30 Vdc / 12 Vdc / 5 Vdc
3 A / 1 A / 1 A
10 mA - 3.2 A / 1.2-1.6 A / 1.2-1.6 A
constant voltage: max. 2 mV
constant current: max. 5 mA
max. 10 mV
max. 5 mA
F1.5AL 250 (order code FU1.5N)
8 hours uninterrupted without overload or short circuit
150 x 145 x 300 mm
4.5 kg
current limitation and short circuit protection
4
5 V "+" output
5 V "-" output
voltage adjustment for 0 - 30 V output
current adjustment for 0 - 30 V output
current limiter indicator for 0 - 30 V output
power switch + power on indicator
©Velleman nv

Publicidad

Tabla de contenido
loading

Tabla de contenido