Leak Detection Function (Lsf) - schmalz X-Pump SXP Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Leak detection function (LSF)

> 3 seconds
> 3 seconds
LSF
LSF
 Press and hold the <DOWN> and <ENTER> keys for at least three
seconds.
When the leak detection function is active, the LEDs for all outputs blink and
the current vacuum value is displayed.
The leak detection function (LSF) is used when setting up the system and for
the subsequent detection of leaks.
In LSF mode, the ejector continuously regulates the vacuum so that any leaks
can be detected acoustically. All diagnostic and monitoring functions are disa-
bled, as are the functions of the keys (except for the combination <DOWN>
and <ENTER>.
The LSF mode can be terminated by pressing <DOWN> and <ENTER> to-
gether.
If the LSF mode is not terminated manually with the key combination
<DOWN> and <ENTER>, it is terminated automatically by the next blow-off
command.
All counters are deactivated when the leak-test function is activated.
Schmalz X-Pump
S
C H MA LZ
Brief operating instructions
4-27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

X-pump sxmp

Tabla de contenido