Testing Your Monitor
Always test your monitor before using it the first time and then on a periodic basis. Before testing your
monitor, complete the setup process as described above.
TESTING THE MOVEMENT FUNCTION
Note: Make Sure your Sensor Pad is set up before proceeding with this section. If you haven't set up your
Sensor Pad please go to page 5 for instructions on how to properly set up the Sensor Pad.
Make sure the Sensor Pad's cord is plugged into the Nursery Unit. Switch the Nursery Unit to the "Sound /
Movement" function . Turn the Parent Unit ON and select either channel A, B or C. Make sure it is set to the
same channel as the Nursery Unit. The green power indicator light will light up. Gently pat your hand on the
mattress. The green Movement Indicator light on the Nursery Unit will flash continuously.
Remove your hand from the mattress. Due to the lack of movement, the Movement Indicator light will stop
flashing, and a pre-alarm beep will sound after 15 seconds. Five seconds later the alarm will sound, the green
Alarm Indicator Light on the Nursery Unit will flash continuously and the green lights on the Parent Unit will
also flash continuously.
IMPORTANT: If the alarm does not sound when you are not touching the mattress, the Sensor Pad may be
detecting a continuous vibration from another source from inside and/or outside your baby's room. Common
sources of this interference are crib mobiles, fans, washing machines or even loud music. Therefore, it is very
important to make sure all vibration sources are eliminated before using the monitor.
Place the crib near a solid supporting wall and away from strong air currents. Do not use crib mobiles or acces-
sories that may cause vibrations. Avoid contact with the crib when the monitor is in use. If you find the alarm
will still not sound when you are not touching the mattress or crib, the monitor is on, and you have removed
all external sources of vibration, the sensitivity level may need to be decreased (Refer to the movement
sensitivity adjustment section on page 7).
Test the stopping of the alarm: to stop the alarm, place your hand lightly on the mattress so that the Sensor
Pad starts detecting movement again. You may also shut the Nursery Unit OFF to stop the alarm.
TESTING THE "TIC" FUNCTION
Make sure the Sensor Pad's cord is plugged into the Nursery Unit. Switch the Nursery Unit to the "Sound /
Movement" function. Turn the Parent Unit ON and select either channel A, B or C. Make sure it is set to the
same channel as the Nursery Unit. The green power indicator light will light up. Gently pat your hand on the
mattress. The green Movement Indicator light on the Nursery Unit will flash and you will hear the Tic sound
with every movement.
Remove your hand from the mattress. Due to the lack of movement, the ticking will stop, the Movement
Indicator light will stop flashing and a pre-alarm beep will sound after 15 seconds. Five seconds later the alarm
will sound, the green alarm indicator light on the Nursery Unit will flash continuousl and the green lights on
the Parent Unit will also flash continuously. To test the sound function, please refer to the Sound Only section
below.
The "Tic" sound will be heard when the Sound & Movement option is chosen. If you do not wish to
hear the "tic", select "tic off" on the right wing of the Nursery Unit.